Specifications

Installation
21
Electrical Connection
Before making any electrical connections to this
unit, check that the power supply is adequate for
the voltage, amperage, and phase requirements
stated on the rating plate.
NOTE: Electrical connection must be performed
by a qualified installer only.
NOTE: The electrical installation must comply
with the national and local codes and in-
stallation requirements.
A strain relief for the supply cord is required. The
installer must provide a supply cord bushing that
meets all local and national installation standards.
A wiring diagram accompanies this manual and is
also attached to the rear of the oven.
SG2136G
SG2136G ovens require a 5 amp, 50 Hz, 1Φ,
230VAC, 3 w ire service consisting of L1, neutral (or
L2) and ground. Use 75_C wire and size to Nation -
al Electric or local codes.
Connect the oven to a separate 230V, 50 Hz p ower
supply with a supply cord and plug or rigid con-
nection and circuit breaker. If a supply cord with
plug is used, the appliance must be positioned so
thattheplugisaccessible.Thecircuitbreakeror
plug must disconnect all poles, including neutral,
with a contact separation of at least 3 mm.
SG2136E
The SG2136E requires a 15 amp, 50Hz, 3Φ,
230/400 VAC, 5 wire service consisting of L1, L2,
L3, neutral and ground.
Connect the oven to a separate 230V, 50 Hz pow er
supply with a supply cord and plug or rigid con-
nection and circuit breaker. If a supply cord with
plug is used, the appliance must be positioned so
thattheplugisaccessible.Thecircuitbreakeror
plug must disconnect all poles, including neutral,
with a contact separation of at least 3 mm.
ConnectL1+L2+L3+neutral+ground.
WARNING!!
Incorrect wiring will result in extensive
damage to electrical co mponents and
possible fire in the control panel.
THE BLODGETT OVEN COMPANY CANNOT AS-
SUME RESPONSIBILITY FOR LOSS OR DAMAGE
SUFFERED AS A RESULT OF IMPROPER IN-
ST ALLATION.