User's Manual
30
6888882V04
Note
If no equipment capable of measuring the 1KW amplifier transmit power is
available, it is possible to use the 1KW amplifier own display to determine the
transmit power. Do not use this method, unless it is absolutely impossible to
obtain appropriate test equipment.
Equipment Turn-On
1. Apply power to the RM125/RM125R by setting its AC power switch to ON (up).
2. Set the AC power switch on the PS unit to ON, and monitor its indications. The expected
indications, as well as what to do if a problem is detected, are described in the below
table.
3. Turn the RM125/RM125R ON/OFF switch and volume control clockwise and adjust for a
comfortable listening level.
4. The 1KW amplifier is also turned on. Monitor its power-up indications. The expected
indications, as well as what to do if a problem is detected, are described in the below
table.
5. Select the prescribed channel and operating mode of the RM125/RM125R. Make sure
that the RM125/RM125R is programmed to use the 1KW amplifier (you should see AMP
on the PROG>RAD>OPTS>ACC menu).
Power-up Indications
Unit
Expected Indication
What to do if not …
PS Unit
AC ON indicator lights
Check that AC power is available, and that the PS
unit is properly connected to the AC distribution
panel
OUT 1 and OUT 2 indicators light.
NG 1 and NG2 indicators off
The PS unit requires service.
Turn the PS unit off: do not attempt to continue
using the 1KW amplifier until the problem is
corrected. You can still transmit and receive using
the RM125/RM125R (maximum transmit power –
125W) by selecting NONE on the
PROG>RAD>OPTS>ACC menu.