The following table lists the 1KW PA Fault and Warning Messages (Cont.)
Type
Message
Meaning
Corrective Actions
Warning
(Cont.)
INVALID FREQ
1KW amplifier could not determine
the operating frequency.
The frequency is measured by
automatically causing the
RM125/RM125R to transmit a low
level (about 5W) pilot tone for a few
seconds after each frequency change,
and also whenever the ENT key of the
RM125/RM125R is pressed
Check the cable connections
between the RM125/RM125R and
the 1KW amplifier.
Repeat the frequency measurement
process by pressing the ENT key of
the RM125/RM125R and monitor
the RM125/RM125R display: it
should switch to the transmit mode
for a few seconds, and its transmit
display should include at least two
bars
1KW PA Rear Panel
Figure identifies the items located on the rear panel of the 1KW amplifier, and the following
table explains their functions.
6
7
5
4
2 3
1
EXCITER CONTROL MONITOR
RF Out
RF In
+48VDC
Figure 4. 1KW PA Rear Panel
Item
Description
Function
1
RF IN Connector
N-type connector for RF connection to the RM125/RM125R:
In the receive or bypass mode, serves as output for receive signals
In the transmit mode, serves as input for RF drive signals
2
+48VDC connector
7-pin circular connector for connection to DC power source
3
Grounding screw
Connection of ground to the 1KW amplifier