Operation Manual

OM-E 2072-09287-00
4-4
Option Description
ERAS
ERAS is used to delete (erase) a channel. Actually, this action only replaces the user-
modified parameters of the channel with the factory-default parameters, but marks the
channel as not programmed.
The factory-default parameter values are as follows:
Rx Frequency 15.000.00 MHz
Tx Frequency 15.000.00 MHz
SSB Mode USB
Bandwidth 2.7
Tx Power MAX
AGC SLOW.
PWR
Select the channel transmit power level. Four transmit power levels can be selected:
LOW – 5 W nominal
MED – 10 W nominal
HIGH – 15 W nominal
MAX – 25 W nominal.
FREQ
Select the channel frequency. Micom Pathfinder offers four frequency options:
SMPX
Simplex Frequency – the same frequency is used for both transmission and
reception.
DPLX
Duplex Frequency – transmits on one frequency and receives on a different
frequency.
RXO
Receiving Only Frequency – defines a frequency for reception only.
Transmission on that frequency is disabled. The available frequency range
is 100 kHz to 30 MHz.
TXO
Transmitting Only Frequency – defines a frequency for transmission only.
You cannot receive on that frequency. The available frequency range is 1.6
to 30 MHz.
BAND
Select the channel operating sideband:
USB upper sideband mode
LSB – lower sideband mode.
MODE
Select the channel radio operating mode:
SSB – single sideband
AME – amplitude modulation equivalent
PLT – single sideband with pilot signal.
AGC
Select the channel Automatic Gain Control mode. Micom Pathfinder offers two AGC
response speeds: SLOW and FAST. You can also turn the AGC OFF completely.
BW
Selects the filter bandwidth.
2.1 – 300 to 2100 Hz
2.7 – 300 to 2700 Hz
3.0 – 300 to 3000 Hz
3.3 – 300 to 3300 Hz. Always select this bandwidth for data transmission
LSM – bandwidth optimized for use with low speed modems (1450 to 1950 Hz)
CW (Continuous Wave or Morse operation). The bandwidth used in this case is
selected by MENU > PROG > RAD > PRMT > CW.