Operation Manual

OM-E 2072-09287-00
3-34
Cont’d
Option
Description
BAND
Toggles between upper sideband (USB) and lower sideband (LSB). The sideband change
takes places only after the current call is ended.
SQ
Toggles the squelch on/off. Always select OFF for CW operation.
DSP
Accesses the Digital Signal Processing menu, which includes the following options:
CLAR
Enables to control the clarifier (off/lower frequency/higher frequency). The
function key is not available for TXO (transmit only) channels.
NF
Enables to control the notch filter (off/lower frequency/higher frequency).
The function key is not available for TXO (transmit only) channels.
CLIP
Toggles the clipper on/off.
NB
Toggles the noise blanker on/off.
ATTN
Toggles the attenuator on/off.
PWR Selects the transmit power level: LOW – 5W; MED – 10W; HIGH – 15W; MAX – 25W.
MODE
Selects the operation mode:
SSB – single sideband
AME – amplitude modulation equivalent
PLT – single sideband with pilot signal).
AGC
Controls the automatic gain control function (fast/slow/off).
BW
Selects the filter bandwidth.
2.1 – 300 to 2100 Hz
2.7 – 300 to 2700 Hz
3.0 – 300 to 3000 Hz
3.3 – 300 to 3300 Hz. Always select this bandwidths for data transmission
LSM – bandwidth optimized for use with low speed modems (1450 to 1950 Hz)
CW (Continuous Wave or Morse operation). The bandwidth used in this case is
selected by MENU > PROG > RAD > PRMT > CW.
RCLV Displays the receive level. The RCLV item appears only if the received signal level display
is not permanently enabled using MENU > PROG > RAD > PRMT > RCLV.
FREQ
Displays the current frequency.
3-12.3.2.2 Replacing the Current Channel While in the Link State
If during an individual call you find that the channel in use is not good enough, you can replace it with
a better channel.
NOTES
Channel replacement is possible only during an individual call in
the ALE mode.
Only the initiator of a call can replace the channel in use.