Installation Instructions

OM-E 2072-09287-00
5-4
Table
5-2. Fault Messages
Message Corrective Actions
OVER TMP Check that the radio is not exposed to direct sun radiation, and that there is no
obstruction to free air flow around the radio
NOT PROG
(Error 14)
This message indicates that the radio is not programmed (the message may
also appear if the radio DC power failed during programming). In this case, the
default baud rate of the MRC interface is 1200 bps.
Program the radio parameters (using the MRC). This forces the radio to accept
the downloaded parameters
BATTERY FAIL
(Error 11)
Micom has an internal battery, that enables the memory to store the last channel
information that was used before the radio was turned off. If this battery
becomes weak, it will display this warning. When the battery is dead, all the
channel information will be retained, but the radio will always use channel 1
when you turn the radio on. (Example: if you are scanning in the ALE mode and
you turn the radio off; when you turn the radio back on, it will be on channel 1).
You may continue using the radio, but request service as soon as possible
DATABASE FAIL
(Error 15)
This message will appear if the ALE scanned channels do not match the
programmed channels in the MRC (for example, ALE is programmed to scan
channels 1, 2 and 3, but the MRC program does not have a frequency
programmed into channel 3).
Check and correct the programmed parameters