Specifications
23
7 - ADJUSTMENT OF THE MINIMUN
OF OVEN BURNER
– Light the oven taking the knob to posi-
tion 10 (max)
– remove the knob and by a thin screw-
driver (3 mm section - 100 mm long)
unscrew of about a half turn the by-
pass, passing through the front panel
hole (see picture below)
– fit the knob and let the oven heat for
10 minutes, then take the knob to
position 1 allowing the thermostat to
work under by-pass G (fig. 8.11).
– after further removal of the knob, stop
slowly the screw by-pass (being care-
ful not to turn the knob) until the flame
reaches 3-4 mm high.
N.B. For LPG the by-pass screw must
be fixed thoroughly.
Fig. 8.11
G