Specifications

18
These operations must be carefully fulfil-
led as follows.
1 - GAS CONNECTION
– The connection must be executed by
qualified technician according to the
relevant standard.
The connection must be executed to
the rear of appliance (fig. 8.1); the pipe
do not cross the cooker.
The unused end inlet pipe of the
cooker (left or right) must be closed
with the plug interposing the gasket.
Gas connection for:
L.P.G. G 30/31
– If not mounted, fit up the holder “R” to
the holder “M” interposing gasket “Q”.
– Connect the cooker to the cylinder
pressure regulator by a suitable rubber
tube (inside diameter 8 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp (not
supplied) to fasten it.
The fitting (fig. 8.2) is made up of:
– 1 adapter “M” for G 20 and G 110
– 1 adapter “R” for G 30/31
– gasket “D” and “Q
D
M
Q
R
Fig. 8.2
Fig. 8.3
Natural gas G 20 - City gas G 110
– Remove the holder “R”.
– Connect the cooker to the gas net by
a suitable rubber tube (inside diameter
13 mm).
Make sure the tube is snugly fit at both
ends and use a standard tube clamp (not
supplied) to fasten it.
– The rubber tube:
- must be as short as possible,
without contractions or kinks;
- must be easy to inspect along its
entire length to check its wear;
- must never be at any point in its
length in contact with the “hot”
parts.
– From time to time check to make
sure that the rubber tube is in
perfect condition and substitute it at
printed due date or if it shows signs
of wearing or damage.
IMPORTANT:
To replace the adapter it is necessary to
operate with 2 spanners (fig. 8.3).
After connecting to the mains, check
that the couplings are correctly sea-
led, using soapy solution, but never a
naked flame.