SEASONAL CLEANING
If the appliance will not be used for a long time:
Pull out the rubber plug to drain off the remaining water.
Operate the appliance in wind mode for 2 hours until the inside is dry.
Turn off the appliance and unplug from electrical mains.
Wash the filter screen and reassemble it.
Dismantle the exhaust duct and keep it properly.
Cover the appliance with a plastic bag and store it at a dry place.
Remove the batteries from the remote control and keep it with the appliance.
INTELLIGENT ERROR DETECTION
Error-detecting code
Multi-functional defection
E2
Error of the room temperature sensor.
E3
Error of the evaporator sensor.
df
Anti-frosting protection: Temperature of the coil is too low and the
appliance will be turned off. When temperature rises above 8ºC, the
protection is released and previous working state will be recovered.
TROUBLESHOOTING
In case of any of the following trouble, please contact service centre for assistance.
Trouble
Cause
Solution
The appliance
doesn’t operate
Plug not connected
Connect the plug to the electrical mains
and switch on the power.
The display panel displays
“Water Full Indicator”
Restart the appliance after power off and
draining, then it will become normal
The appliance starts
frequently
Direct sunlight
Draw the curtain
Doors and windows keep
open; there are lots of heat
sources in the room
Close doors and windows, remove heat
source
Filter screen is very dirty
Clean or replace it
Air inlet or air outlet is blocked
Remove the blocking item
Loud noise of the
appliance
The appliance is placed
unevenly
Place it at even and firm ground, avoid
shaking
The compressor
doesn’t work
Its delay protection is started
Wait for 3 minutes, unit will turn on after
the time delay protection.
Notice: When there is any abnormal operating condition to the appliance, turn it off and unplug from