Owner`s manual

SEASONAL CLEANING
If the appliance will not be used for a long time:
Pull out the water wedge to drain off the remaining water.
Operate the appliance in wind mode for 2 hours until the inside is dry.
Turn off the appliance and unplug from electrical mains.
Wash the filter screen and reassemble it.
Dismantle the exhaust duct and keep it properly.
Cover the appliance with a plastic bag and store it at a dry place.
INTELLIGENT ERROR DETECTION
Error-detecting code Multi-functional defection
E1 Error of the coil’s temperature sensor
E2 Error of indoor temperature sensor
E4 Anti-freezing protection: Temperature o
f the coil is too low and the
appliance will be turned off. When temperature rises above 8ºC, the
protection is released and previous working state will be recovered.
TROUBLESHOOTING
In case of any of the following trouble, please contact service centre for assistance.
Trouble
Cause
Solution
The appliance
doesn’t operate
Plug not connected Connect the plug to the electrical mains
and switch on the power.
The display panel displays FL Restart the appliance after power off and
draining, then it will become normal
The appliance starts
frequently
Direct sunlight Draw the curtain
Doors and windows keep
open; there are lots of heat
sources in the room
Close doors and windows, remove heat
source
Filter screen is very dirty Clean or replace it
Air inlet or air outlet is blocked Remove the blocking item
Loud noise of the
appliance
The appliance is placed
unevenly
Place it at even and firm ground, avoid
shaking
The compressor
doesn’t work
Its delay protection is started Wait for 3 minutes, turn on after
temperature decreases
Notice: When there is any abnormal operating condition to the appliance, turn it off and unplug from
electrical mains, contact service centre for maintenance.
10