Specifications

29
LUBRICATION OF THE GAS TAPS
• Incaseofdifcultyinthegastapsoperation,callService.
IMPORTANT
All intervention regarding installation maintenance of the appliance must be fullled with
original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 28-30 mbar
G31 37 mbar
Natural Gas
G20 20 mbar
Town Gas
G110 8 mbar
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Semi-rapid (SR) 1,75 0,45 66 101 192
Rapid (R) 3,00 0,75 87 129 280
Triple-ring (TR) 3,50 1,50 93 135 310
AIRVENTNECESSARYFORGASCOMBUSTION=(2m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring (TR) 7,00
GAS MAINTENANCE