Specifications

27
• theexiplepipedoesnotexceed2000mminlength(orrefertoapplicablelocalregula-
tions) and does not come into contact with sharp edges, corners or moving parts. Use
asingleexiblepipeonly;neverconnectthecookerwithmorethanoneexiblepipe.
• theexiblepipecaneasilybeinspectedalongitsentirelengthtocheckitscondition;ifit
has an expiry date, it should be replaced before that date.
• ifusingaexiblepipewhichisnotentirelymadeofmetal,makesurethatitdoesnot
come into contact with any part of the cooker with a surface temperature of 70°C or
above (or refer to applicable local regulations).
• thehoseisnotsubjecttoexcessiveheatbydirectexposuretoueproductsorbycon-
tact with hot surfaces.
• therigidorexiblepipeisreplacedifitshowssignsofwearordamage.
• a gas pressure regulator, in compliance with the applicable local regulations, is installed
when connecting to an LPG cylinder.
• you inform the customer that the cylinder valve or the supply valve immediately by the
appliance should be closed when the cooker is not in use.
• youinformthecustomerthattherigidorexiblepipeshouldnotbesubjectedtocorro-
sion by acidic cleaning agents.
After connecting the cooker to the gas supply, make sure that you
• check that the connections are correctly sealed using a soapy solution, but never a
nakedame.
• check whether the injectors are correct for the type of gas being used. If not, follow the
instructions under “GAS MAINTENANCE”.
• replace the sealing washer/s on the slightest sign of deformation or imperfection. The
sealing washer/s is/are the part/s which guarantee/s a good seal in the gas connection.
• usetwospannerswhenconnectingtherigidorexiblepipe(Fig.8.3).
Gas connection with rigid or exible pipe
Note:ifalreadyttedontheinletpipe,
remove the rubber hose holder
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) male
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
1/2” G cylindrical
(ISO 228-1) female
(#)Ifnotalreadyttedontheinlet
pipe, it is supplied with the
appliance in a separate kit
Inlet pipe
Manifold male
pipetting
Sealing washer (#)
Sealing washer (#)
Brass connector (#)
Flexible pipe
(not supplied)
Rigid pipe
(not supplied)
Fig. 8.3