Specifications

80
Ventilation options
EXTERNAL DUCTING
THROUGH A SIDE
WALL OR CEILING
RECIRCULATION
RECIRCULATES FILTERED AIR
BACK INTO THE KITCHEN
EXTERNAL DUCTING
RECIRCULATION
Rangehoods can be ventilated to either
external ducting or recirculation. The diagrams
illustrate the dierences between the two
options. Refer to installation instructions for
specific models for more detailed information
on ventilation.
Ducted Recirculating
Rangehood Ducting Guide Top Ducting (Roof) Top Ducting (Sot) Rear Ducting
HF60CI / HF90CI RR1608 + RR1613 RR1608 + RR1687 RR1687 791841
HS60CS / HS90CS
A* RR1570 + RR1571 or
B* RR1637 + RR1613
A* RR1570 + RR1596 (x2) + RR1600 or
B* RR1637 + RR1687
RR1575
RR1495 (60 mm)
R103795C (90 mm)
HS60CI RR1570 + RR1571 RR1570 + RR1607 + RR1636 RR1575 RR1495
HC60PCI / HC60PCHT RR1634 + RR1635 RR1634 + RR1688 RR1688
790681
HC90PCHT RR1634 + RR1635 RR1634 + RR1688 RR1688
HC90CGX1 / HC90DCXB1 /
HC120DCXB1
RR1634 + RR1635 RR1634 + RR1688 RR1688 791820
HI120MVBX1 / HC90MVBX1 791531
A* All rectangular ducting B* Ducting outlet adopted to 125mm round, then to round ducting.
This is only a guide and is true for a standard installation. Dierent installations may need further parts. Extra lengths and/or bends may be required depending on the
length required and whether there is any structural material in the run, eg, rafters. Please note this chart is designed as a guide only, please consult with a trained UNIDUCT
consultant if unsure.
Rangehood Optional Accessories
All accessories can be purchased through your Fisher & Paykel dealer or through Fisher & Paykel Spare Parts.
Fisher & Paykel Spare Parts 0800 287 746, Fisher & Paykel Customer Care 0800 FP CARE, or online at www.fisherpaykel.co.nz