DMX ADDRESSING
Setting the DMX Address - After the fixture is turned “ON” it will immediately complete a
reset process that tests all the fixture’s functions. When the reset process concludes the
LCD will display the fixture’s current DMX address. If the fixture is not receiving a DMX
signal, the display will flash continuously. To set or adjust a DMX address, please follow the
procedure below:
1. Toggle through the menu by pressing UP and DOWN until the display reads
“Addr=XXX”. Press ENTER to make changes to the address.
2. While the display is flashing use UP and DOWN to select a new address. Once
the new address has been selected, lock the new address into the fixture’s
memory by pressing ENTER.
The DMX address is non-volatile and will remain in the fixture’s memory even when the
power to the unit is switched off. Memory is backed-up and retain by an internal power
source that should last about five years.
Remote DMX addressing (RDMX) / Address Via DMX- This function allows the DMX
address to be changed remotely from a DMX console. This setting requires special settings
for both the controller and the fixture, and may be turned ON and OFF. (“ON” = default)
Fixture Settings:
1. Access the main menu and use UP or DOWN to get to the “Personality”
menu, then press ENTER.
2. Once in the “Personality” menu, press UP or DOWN to get to the
“Status Settings” menu, press ENTER.
3. Once in the “Status Settings” press UP or DOWN to get to the “Address
via DMX” function and press ENTER.
4. “Address via DMX” is the function that turns the RDMX function ON and
OFF. Press ENTER and be sure the function is turned on.
5. Press UP to display “ON” to activate or “OFF” to deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.