VER
Use this function to display the Software version of the unit.
1. Access the main menu.
2. Press UP until “SPEC” is displayed, press ENTER.
3. Tap UP until “VER” is displayed, press ENTER.
4. The display will show “V-1.0, the display may also show, “V-2.0”, “V-9.9” etc.
5. Press ENTER or MODE/ESC to exit.
ADJU
This function is used to calibrate the various internal motors in the event the
internal homing mechanism become slightly out of adjustment. This function is protected
with a password to prevent unauthorized personal from tampering with the fixture.
1. Access the main menu.
2. Press UP or DOWN until “ADJU” is displayed, then press ENTER.
3. Press UP or DOWN until “CODE” is displayed, then press ENTER.
4. The display will show “CXXX”, were as “XXX” represents the calibration
password. The calibration password is “C050”. Use UP or DOWN to enter the
proper password.
5. Once the proper password is entered the display will read “CHXX”, were as
“XX” represents the fixture channel number, in the case of the E SPOT LED
II™ 1 ~ 16.
6. Select the desired channel to be calibrated by pressing UP or DOWN and then
ENTER to confirm.
7. The display will then read “xxxx”, were “xxxx” stands for the calibrate values.
8. Adjust the desired calibration value between –128 and 127 by pressing UP and
DOWN. As you scroll up and down through the calibration values you will notice
slight changes in the wheel or motor you are attempting to calibrate.
9. Once you reach your desired calibration press ENTER to confirm and lock in
your calibration.