User manual

Power Spot 575IE™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 9
1. Lens Assembly - This high quality lens is a fully focusing. Focus the lens by
manually turning the lens in a clockwise or counter-clockwise direction until the desired
effect is achieved.
2. DMX Input Jack – This 3-Pin XLR jack is used to receive an incoming DMX signal.
3. DMX Output Jack – This 3-Pin XLR jack is used to send an outgoing DMX signal.
For best results this jack should be terminated if it is the last fixture in a DMX daisy-
chain (see termination on page 14).
4. Microphone Sensitivity Adjustment Knob This knob is used to adjust the
frequency sensitivity of the internal microphone when operating in “audio” mode.
When the knob is turned counter-clockwise the unit is less sensitive to sound. When
the knob is turned clockwise the unit is more sensitive sound.
5. Firmware Connection This connection is designed to be used solely by an
authorized technician to upgrade the operating software and to test the fixture.
6. Internal Cooling Fan This fixture is equipped with two high-velocity variable
speed fans mounted in the base to aid in the cooling process. These fans are
designed to vary their velocity at different operating temperatures. When the fixture
reaches a predetermined internal operating temperature the fans function at high
speeds. The higher speeds provide better cooling associated with higher operating
temperatures during long use. When the fixture is operating at a lower temperature
the fans operate at low speed. Be sure to keep all vents clean, blocked cooling
vents can shorten lamp life and reduce the fixtures reliability. For more information on
the fan functions see page 23, section 3.9.7.
7. Base The main base holds the majority of the electronics and logic boards. The
base also provides a means to securely mount the fixture to the floor or ceiling.
8. Retaining Arm These arm hold the head in place and provide a means of tilt
movement. These arms also provide a conduit for all the electronics traveling from the
base to the head.
9. Lamp Fuse Holder This housing holds a 8A/250V GMA fuse. Never defeat this
fuse, this fuse is designed to protect the lamp in the event of severer power
fluctuations. In the event of fuse failure, always be sure to replace this fuse with an
exact match unless otherwise instructed by an authorized Elation technician.
10. Electronics Fuse Holder This housing holds a 1A/250V GMA fuse. Never
defeat this fuse, this fuse is designed to protect the electronics in the event of severer
power fluctuations. In the event of fuse failure, always be sure to replace this fuse
with an exact match unless otherwise instructed by an authorized Elation technician.
11. Powercon Connector This power jack is designed to be used only with the
Neutrik Powercon adapter included with your fixture. This jack provides main power
to your fixture.