User manual

Power Spot 575IE™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 35
components.
6.2.5 Replace the lamp with an approved replacement type. Be sure to follow all the lamp
handleing procedures included with your new lamp. Never handle the new lamp with
your bare hands, the oils from your skin may damage the lamp. Always replace with
the lamp with a lamp that meets the orginal lamp specification, failure to do so may
damage the unit and will void your manufactures warranty.
6.2.6 Before reassembing the unit, be sure the new lamp is securely seated in lamp
socket.
6.2.7 Reassemple the unit in reverse order.
6.2.8 Besure to reset the lamp running time in the “TIME“ menu. The lamp run time is
designed to function as lamp replacement reminder (see page 20).
Attention:
Be sure the lamp is securely seated in the lamp socket. Failure to comply
with this warning may cause excessive heat build-up that may cause the
internal lens to crack.