User manual

Power Spot 575IE™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page 25
3.10 Display Error and Information Messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes
after having switched off (lamp too hot). The message will appear on the
display if the lamp doesnt ignite within 20 seconds. The fixture will store
this command and automatically ignite the lamp after 5 minutes.
IG E
When igniting the lamp, the electronic ballast will examine whether the
lamp ignited or not. If the lamp does not ignite within 20 seconds, the
igniting sequence is terminated. The fixture will wait approximately 2
minutes and attempt the lamp ignition process once again. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped and the
display reads "IG E" (Ignition error).
LAER
After the ignition of the lamp was two times not successful the display will
show LAER. That means the lamp could be damaged or even missed,
the fixture is overheating or there could be a failure on the igniter or ballast.
Switch off the power supply and solve the possible problem.
After the error "IG E" respectively "LAER" it is not anymore possible the start the lamp
via Shutter = 255. Nevertheless if a renewed ignition attempt is desired, first run a
Reset (at the Spot or over DMX). Afterwards you can try again to ignite the lamp.
OTMP
This error message informs you that the fixture was overheating and lamp
has electronically been switched off to allow the fixture to cool to normal
operating temperatures. Please look for any possible reason that may
have caused the fixture to overheat. i.e., faulty fans, air vents blocked or
dirty, lamp broken or very old, too high ambient temperature. Switch off
the power supply and solve the possible problem.
RsER
This message informs you that one of the fixture function wasnt able to do
its reset correct (magnetic sensor, stepping motor, driver on the PCB,
cables, etc.). Repair the defect and start the fixture again.