3.9.5 Display
DISP
Use this function to choose between different display indications. Use the
Up/Down-keys to select desired function and press Enter to confirm or Mode to
cancel and return to the menu.
D ON
Display On/Off (If you've chosen off, the display will go out within
15 seconds after the last input. The next key touch will reactivate the
display).
REV
Rotates the display by a 180˚ - This may also be accomplished by
pressing both the “UP” and “DOWN” buttons at the same time.
3.9.6 Fixture Temperature
TEMP
This function allows you to read out the actual fixture operating temperature. Press
the Enter button to select this function or the Mode to button to cancel and return
to the main menu. Normal operating temperature should range between 85˚C
and 95˚C. Operating temperatures between 96˚C and 104˚C are considered
critical. Temperatures above 105°C will send the fixture into protect mode and
automatically switch the lamp off, the lamp will remain off until internal temperature
drops below 95˚C. Outside surface temperature should not exceed 45˚C.
3.9.7 Fan Control
FANS
By using this function you can choose between 4 types of fan speed operations.
Use the Up and Down buttons to select the desired fan setting, then press
Enter to accept your setting or press the Mode button to cancel and return to the
menu. The chart below will detail the different fan settings:
HIGH
The cooling fan works continuously at max. speed.
This is the default fan setting. In this setting an internal thermal sensor
constantly monitors the internal operating temperature and regulates
the fan speed to coincide with the internal temperature.