FIXTURE INSTALLATION
The$electric$connection$must$only$be$carried$out$by$a$qualified$electrician.$
CAUTIONS
For added protection, mount the fixture in areas outside walking paths, seating
areas, or in areas were unauthorized personnel might reach the fixture.
Max ambient operating temperature for this fixture is 113°F. (45°C)
Do not use the fixture under or above this temperature.
Before mounting the fixture to any surface, make sure the installation area can
hold a minimum point load of 10 times the weight of the fixture. 105 lbs / 48 kg)
Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable.
Never stand directly below the device when mounting, removing or servicing.
POWER LINKING
Max number of units that can be power linked is 10 units @120V.
CLAMP MOUNTING
The OPTI QA PAR
provides a unique integrated Dual Yoke / Floor Stand. When
mounting this fixture to truss be sure to secure an appropriately rated clamp using
an M10 screw fitted through the center hole of the Dual Yoke / Floor Stand.
SECURING
Regardless of the rigging option you choose for your OPTI QA PAR
always be sure
to secure your fixture with a safety cable. The fixture provides a built-in rigging point
for a safety cable on the hanging bracket as illustrated above. Be sure to only use
the designated rigging point for the safety cable and never secure a safety cable to
a carrying handle.