Design LED 12 Brick Elation Professional™ 4295 Charter Street Los Angeles, Ca 90058 www.elationlighting.com Rev.
DESIGN LED 12 BRICK™ ©Elation Professional, Los Angeles Ca. 1 www.ElationLighting.
DESIGN LED 12 BRICK™ TABLE OF CONTENS CONTENTS 1. General Information……………………………………………………………………… 3 a. Introduction………………………………………………………………………. 3 b. Unpacking………………………………………………………..…………..… 3 c. Customer Support…………………………………………….………………… 3 d. Warranty Registration……………………………………………………..…… 4 2. Safety Instructions………………………………………………………........…………. 5 3. Features…………………………………………………………………………………… 7 4. General Guidelines………………………………………………………………………. 8 5. Fixture Overview…………………………………………………………………………. 9 6.
DESIGN LED 12 BRICK™ 1. GENERAL INFORMATION INTRODUCTION: Congratulations, you have just purchased one of the most innovative and reliable LED fixtures on the market today! The Design LED 12 Brick,™ has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit.
DESIGN LED 12 BRICK™ yourself. Doing so will void your manufactures warranty. Please do not discard the shipping carton in the trash. Please recycle whenever possible. WARRANTY REGISTRATION: The Design LED 12 Brick™ carries a two year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A.
DESIGN LED 12 BRICK™ 2. SAFETY INSTRUCTIONS To guarantee proper and consistent operation, it is important to follow the guidelines in this manual. Elation Professional will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. 1. Always be sure that the fan and the air inlets remain clean and are never blocked. Allow about 6” (15cm) between this fixture and other devices or a wall to allow for proper cooling. 2.
DESIGN LED 12 BRICK™ replace it immediately with a new one of similar power rating. 13. Always disconnect from main power before performing any type of service or any cleaning procedure. 14. Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. 15. Please be aware that damages caused by modifications to the device are not subject to warranty.
DESIGN LED 12 BRICK™ 3.
DESIGN LED 12 BRICK™ 4. GENERAL GUIDELINES This fixture is a professional lighting effect designed for use on stage, in nightclubs, in theatres, and other types of architectural installations. Do not attempt operation or installation without a proper knowledge on how to do so. This fixture was designed for indoor use only; use of this fixture outside will void the manufacture’s warranty. Consistent operational breaks will ensure that the fixture will function properly for many years to come.
DESIGN LED 12 BRICK™ 5. FIXTURE OVERVIEW 1. Hanging Bracket – The unit uses a unique sectional bracket that allows the unit to be hung, mounted, or stood straight up. 2. Bracket Locking Knob – This knob is used to secure the bracket in place after angle adjustments have been made. ©Elation Professional, Los Angeles Ca. 9 www.ElationLighting.
DESIGN LED 12 BRICK™ 3. DMX In Jack – This jack accepts an incoming DMX signal via a male, 5-pin XLR jack. 4. DMX Out Jack – This jack is used to send an incoming DMX signal to the next fixture in the DMX chain via a female, 5-pin XLR jack. 5. DMX In Jack – This jack accepts an incoming DMX signal via a male, 3-pin XLR jack. 6. DMX Out Jack – This jack is used to send an incoming DMX signal to the next fixture in the DMX chain via a female, 3-pin XLR jack. 7.
DESIGN LED 12 BRICK™ 6. MOUNTING AND INSTALLATION Yoke Assembly – Single Unit Operation The device can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics. When connecting the hanging yoke to the fixture, refer to the illustration below. Yoke Assembly – Multiple Unit Operation You can connect up to four Design LED 12 Bricks together in a bar assembly.
DESIGN LED 12 BRICK™ Please note: To ensure maximum stability, no more than for units should be mounted together in this fashion. Connecting more than four units will result in an unstable assembly, which could collapse and damage the units. Cautions: For added protection mount the fixtures in areas outside walking paths, seating areas, and away from areas were the fixture might be reached by unauthorized personal.
DESIGN LED 12 BRICK™ Mounting The Design LED 12 Brick™ is fully operational in three different mounting positions, hanging upside-down from a ceiling, side mounted, or set on a flat level surface. Be sure this fixture is kept at least 0.5m away from any flammable materials (decoration etc.). When clamp mounting; always use and install the supplied safety cable as an added safety measure to prevent accidental damage in the event of a clamp failure. See the image below.
DESIGN LED 12 BRICK™ CAUTION! Be sure all electrical connections are performed by a qualified electrician before attempting any operation. Clamp Mounting The Design LED 12 Brick™ provides a unique mounting bracket assembly that allows the unit to stand on flat surface, hang on truss via a clamp, or be used in cluster allow multiple units to rigged together (see the illustration below).
DESIGN LED 12 BRICK™ Securing the Design LED 12 Brick™ Always be sure to secure your fixture with a safety cable when suspending the unit from truss or other means. The fixture provides a built-in rigging point for a safety cable as illustrated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to the hanging bracket. ©Elation Professional, Los Angeles Ca. 15 www.ElationLighting.
DESIGN LED 12 BRICK™ 7. UNDERSTANDING DMX Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation): Your fixture and your DMX controller require a standard 3-pin XLR connector for data input and data output (see figure below). Be sure to only use properly rated DMX cables for DMX operation and not standrd audio cables.
DESIGN LED 12 BRICK™ Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™. DMX-512 connection with DMX terminator When longer runs of cable are used, you may need to use a terminator on the last fixture to avoid erratic behavior. A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -).
DESIGN LED 12 BRICK™ Understanding Fixture DMX addressing; All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of this starting DMX address is achieved by combining various dipswitches located on the rear of the fixture.
DESIGN LED 12 BRICK™ 8. OPERATING MODES This fixture can run in three different DMX modes. The chart below describes how to access the different DMX modes. The chart below also defines the how the channel will function in the different DMX modes.
DESIGN LED 12 BRICK™ Preset Program 2 ON OFF ON OFF OFF OFF OFF ON OFF Preset Program 3 ON OFF ON OFF OFF OFF ON OFF OFF Preset Program 4 ON OFF ON OFF OFF ON OFF OFF OFF Preset Program 5 ON OFF ON OFF ON OFF OFF OFF OFF Preset Program 6 ON OFF ON ON OFF OFF OFF OFF OFF Preset Program 7 ON OFF ON OFF OFF OFF OFF ON ON Preset Program 8 ON OFF ON OFF OFF OFF ON OFF ON Manual static color settings are achieved when dipswitch 7 is in the “of
DESIGN LED 12 BRICK™ Dipswitches 1 & 7 on accesses internal program 1 Dipswitches 2 & 7 on accesses internal program 2 Dipswitches 3 & 7 on accesses internal program 3 Dipswitches 4 & 7 on accesses internal program 4 Dipswitches 5 & 7 on accesses internal program 5 Dipswitch 6 & 7 on accesses internal program 6 Dipswitch 1,2 & 7 on accesses internal program 7 Dipswitch 1,3 & 7 on accesses internal program 8 The chart below details the different speed settings available for the internal programs when the fi
DESIGN LED 12 BRICK™ 9. DMX CHANNEL TRAITS 6 Channel Mode: This chart details a simple layout of the DMX channel assignment in 6-channel mode. The chart traits will vary slightly for 12 channel and 15-channel operation, as those modes use more RGB channels for more precise control. CHANNEL 1:Red CHANNEL 2:Green CHANNEL 3:Blue CHANNEL 4: Internal programs: CHANNEL 5:Strobe CHANNEL 6: Dimming (0%-100%) ©Elation Professional, Los Angeles Ca. 22 www.ElationLighting.
DESIGN LED 12 BRICK™ DMX channel’s functions and their values (6 Channel Mode): Channel 1 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 2 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 3 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 4 - Internal programs: 0-10 No function 11-40 Internal program 1 41-70 Internal program 2 71-100 Internal program 3 101-130 Internal program 4 131-160 Internal program 5 161-190 Internal program 6 191-220 Internal program 7 221-255 Internal pr
DESIGN LED 12 BRICK™ Channel 6 - General dimming / Program Speed Control This channel has two functions depending on the operating mode. When running the built-in programs this channel will control the program speed. 0-255 Dimming (0%-100%) ~ Normal Operation 0-255 Speed (min to max) ~ When running built-in programs on channel 4 12 Channel Mode: This chart details a simple layout of the DMX channel assignment in 12-channel mode. In this mode all channels are used to control the various RGB LEDs.
DESIGN LED 12 BRICK™ Channel 3 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 4 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 5 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 6 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 7 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 8 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 9 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 10 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 11 - Green: 0-255 Green
DESIGN LED 12 BRICK™ 15 Channel Mode: This chart details a simple layout of the DMX channel assignment in 15-channel mode. In this mode channels 1~12 are used to control the various RGB LEDs and channels 13~15 will control special features.
DESIGN LED 12 BRICK™ Channel 5 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 6 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 7 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 8 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 9 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 10 - Red: 0-255 Red (0-Black, 255-100% Red) Channel 11 - Green: 0-255 Green (0-Black, 255- 100% Green) Channel 12 - Blue: 221-255 Blue (0-Black, 255- 100% Blue) Channel 13 - Internal progr
DESIGN LED 12 BRICK™ 101-130 Internal program 4 131-160 Internal program 5 161-190 Internal program 6 191-220 Internal program 7 221-255 Internal program 8 Channel 14 - Strobe: 0 No function 1~95 Strobe effect slow to fast 96-127 No function 128-159 Pulse effect in sequences 160-191 No function 192-223 Random strobe effect slow to fast 224-255 No function Channel 15 - General dimming / Program Speed Control This channel has two functions depending on the operating mode.
DESIGN LED 12 BRICK™ ©Elation Professional, Los Angeles Ca. 29 www.ElationLighting.
DESIGN LED 12 BRICK™ 10. CLEANING AND MAINTENANCE The consider the following point during normal service and inspection: 1. Be sure all screws and fasteners are securely tightened at all times. Lose screws may fall out during normal operation resulting in damage or injury as larger parts could fall. 2. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable.
DESIGN LED 12 BRICK™ 11. 2-YEAR LIMITED WARRANTY A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional® products to be free of manufacturing defects in material and workmanship for a period of two years, (730 days) from the date of purchase. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories.
DESIGN LED 12 BRICK™ effect. E. Elation Professional® reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above.
DESIGN LED 12 BRICK™ 12. PHOTOMETRIC DATA Distance 1m 2m 3m Diameter 0.8m 1.6m 2.4m A1 480 144 76 ©Elation Professional, Los Angeles Ca. B1 368 129 68 33 B2 370 129 74 B3 340 124 72 B4 304 122 69 Average 372 648 72 www.ElationLighting.
DESIGN LED 12 BRICK™ 13. DIMENSIONAL DRAWINGS ©Elation Professional, Los Angeles Ca. 34 www.ElationLighting.
DESIGN LED 12 BRICK™ 15. TECHNICAL SPECIFICATIONS Power supply: 90V~250V AC50Hz~60Hz Power consumption: MAX LED Configuration: 12 1Watt Units (3 x Red, 3x Green 3 x Blue) Packing dimensions: 47x26.5x19cm (56x48x42cm ~ 4pc system) Weight: 2.1Kgs / 4.62 Lbs (9.2Kgs ~ 4pc system) DMX Channels: 15, 12, or 6 Channel mode Drive: Standard DMX-512, 3 pole XLR; [+] = Pin 3 30W [-] = Pin 2 [Ground] = Pin 1.
DESIGN LED 12 BRICK™ ©Elation Professional, Los Angeles Ca. 36 www.ElationLighting.
DESIGN LED 12 BRICK™ Elation Professional 4295 Charter Street Los Angeles, CA. 90058 323-582-3322 / 323-582-3108 fax www.ElationLighting.com /Info@ElationLighitng.com ©Elation Professional, Los Angeles Ca. 37 www.ElationLighting.