Instruction manual

Controls & Functions:
Front Panel View
ArtNet encoder:
To activate and set SubNet and Universe of ArtNet. And use Universe encode to set the starting number of the
existing node's Universe.
Power Indicator:
Ethernet port:
Link/Data Indicator:
Link/Data Indicator:
250K/1000K indicator:
Work Mode Selector(SW1~2):
To indicate the work status of the unit.
With RJ 45 standard network port.
To indicate the status of network linking and data linking.
To indicate the status of network linking and signal/data linking.
To indicate the signal output of 8 Universe DMX uses standard DMX-512 protocol or high speed DMX-1000K.
To select and activate the Control Protocol as you desire;
SW1 SW2 Control Protocol
OFF X
ON X
ArtNet Protocol
CL100M Protocol
SW1
OFF
SW2
ON
Special Note:
1.Under ArtNet protocol, you MUST firstly set your PC's IP address of "2.16.0.3", and Subnet mask addressing
of "255.0.0.0"
2.Under CL100M protocol, the X-Net Configuration software from Elation will be available. You MUST firstly
set your PC's IP address of "172.16.0.3", and Sub mask addressing of "255.255.255.0".
.
(How to set your PC's IP addressing and Subnet mask addressing, please refer to "Configuring Ethernet card".)
3.Once you-reset Sw1 or Sw2 if you need, you MUST restart your E-NODE 8
DMX Trigger Interface(XLR male connector):
To feature DMX trigger function which is used to control Show by connecting DTC-512 or X-Trigger-USB.
(For further information, please refer to its accompanying user manual.)
DMX Channel Selection
Starting Channel
Starting Channel
+1
Starting Channel
+2
DMX Values & Functions
0~127 to Normal Output,
129~255, allow to Blackout.
0~85 to Pause;
86~170 to Play;
171~255 to allow to Stop.
0 ~2, select Scene_1;
3~5, select Scene_2;
6~8, select Scene_3;
........
252~254, select Scene_85
DMX Channel Selection, DMX Value & Functions Table
1. DMX starting Channel is available to be set by operating X-Net Configuration software.
2. For Downloading DMX data files, Editing Show and Event Triggering, please refer to user manual of
E-NODE 8 Configuration Software.
DMX Interface(1~8 DMX Universe):
To output DMX control signal
Back Panel View
Fuse Holder:
To mount the fuse of F3.15A, 250V 5*20mm
-5-