Should the DMX signals be disabled, operation can be done manually.
6.4 DMX TRIGGER mode
In this mode, the first four DMX channels (Ch1~Ch4) can be used to respectively
control
I01~I04 sequences. I01~I04 sequences will run when the DMX level of each
relative channel !20%. These sequences will stop running when the correspondent
level _20%.
The DMX trigger will only operate when it is receiving a DMX signal.
Sequences (including STARTUP and SHUTDOWN) can be operated manually in
DMX TRIGGER mode.
6.5 PROGRAM mode
In this mode, any one of the sequences can be recorded, and the sequence name
can also be changed.
6.5.1 Recording operation
Select the sequence to be recorded (including the internal sequences and the
external sequences). Remember: The CF card must be formatted before use.
Check DMX indicator. When the correspondent LED is “on”, the unit is receiving a
DMX signal, when the LED is “off” the unit is not receiving a DMX signal.
Press the RECORD button, the sequence control will be paused, and the
correspondent data will be erased.
Press the PAUSE or PLAY button to record. Then press the STOP button to stop the
operation at any moment you want.
Warning: during operation, please do not turn off the unit, otherwise the
correspondent recorded data will be missing.
6.5.2 Changing the sequence name
In PRG Mode, when the unit is “STOPPED”, press the “Enter button to enter the
menu, an underline will appear in the top left corner of the LCD-display.
Press the NEXT button to move to the selected character, and use UP/DOWN
buttons to change the correspondent characters. Press ENTER button to confirm
your operation.
The Smpte time will not change while changing the sequence name.
6.6 SETUP mode
Seven items are offered and can be selected in this SETUP mode as below.
(1) Smpte Trig : enter this submenu to trigger the Smpte signals and to set the trigger
time. Press the NEXT button, and then use the UP / DOWN buttons to choose Yes