8. If the lamp protection circuitry has already been initiated and the lamp run time is
not reset the “Replace the Lamp” warning will continue to flash in the display and
the fixture will eventually shut down. To reset the lamp running time follow the
procedures below;
A. Activate the menu by pressing the “Mode/Esc” button and toggle to
“Information”
B. Once at “Information” tap the “Enter” button and use the “Up” or “Down”
buttons to toggle to “Time Information”
C. Once at “Time Information” us either the “Up” or “Down” buttons to toggle
to “L-Timer Password” and tap the “Enter” button. Then use the “Up” or
“Down” buttons to enter the reset pass code, “038” and tap the “Enter”
button once again. The display will automatically revert to “L-Timer
Password,” next toggle down to “Clear Lamp Time”
D. Once at “Clear Lamp Time” tap the enter button and select “ON.” The
lamp timer has now been reset, use the “MODE/ESC” button to exit the
menu and return to the home screen.
Lamp Optimization
Unlike traditional discharge lamps the Platinum 15R lamp does not require optimization.
The lamp orientation and optimization procedure has been preset during the
manufacturing process of the lamp.
Please remember that a MSD Platinum 15R lamp is not a hot-restrike lamp therefore, you
must wait approximately 15 minutes before you can attempt to strike the lamp once it has
been turned off.