Product Manual Elastilon – The Revolutionary Self Adhesive Hardwood Flooring Installation System For technical information, please visit our website www.elastilonusa.com or contact us at 1-877-526-9663 or email us at info@elastilonusa.com . Version 1.
Elastilon Product Manual Table of Contents: Product Knowledge --------------------------------------------------------- 2 o o o o o o What Is Elastilon and how does it work? Features & Benefits Elastilon Simple Facts Warranty Information Installation has never been easier Questions and Answers Installation Tips - Before You Begin ------------------------------------ 15 Board Replacement Instructions ----------------------------------------- 17 How to become certified on Elastilon ----------------
Elastilon Product Manual Product Knowledge What Is Elastilon and how does it work? What is it? 1. Elastilon is a revolutionary Self Adhesive Installation System used in the installation of solid and engineered hardwood floors in any room including the basement. Floors are installed directly onto the Elastilon adhesive surface over just about any sub-surface including directly over concrete. 2.
Elastilon Product Manual 4. Ideal for those hardwood species that have moderate to high expansion/contraction characteristics including species that include maple & exotics such as bamboo. 5. Closed cell foam pad (50kg/m³) provides cushion for superior comfort and reduced impact noise. Up to an IIC 62 rating in use with ¾” hardwoods over a 6” concrete flooring system. 6. Easy peel off system allows for quick installations.
Elastilon Product Manual Elastilon Simple Facts Strong Thickness – 3mm (.12 in) – Single Sided Adhesive Roll length – 10m (32.81 ft) Roll Width -- 1m (3.281 ft) Coverage per roll – 10m² (107.64 sq ft) Foam Density – 50kg/ m³ IIC 62 STC 54 (in combination with 3/4” flooring and Elastilon Strong) Warranty Information Elastilon Guarantees the glue layers used on all different Elastilon Systems will maintain its quality and strength, for at least 70 years after production.
Elastilon Product Manual Installation has never been easier Clean floor completely. In all below-grade applications, always add an approved 6 mil polyethylene film vapor barrier before laying the Elastilon. For concrete floors that are on-grade or above-grade, if the moisture parameters are higher then the allowed levels or the moisture levels cannot be determined, a 6-mil polyethylene film vapor barrier must be installed.
Elastilon Product Manual When the first two rows are in position, apply forward pressure to the two rows so that the joint between them is seamless; simply pull the white protective starter strip out from under the board to the edge of the flooring being careful not to expose the adhesive face. If this occurs, just tuck the protective foil back under the edge of the already installed floor board.
Elastilon Product Manual Questions and Answers Is Elastilon user friendly? Elastilon installs 50 to 70% faster than traditional glue down and other hardwood flooring installations. It requires no messy glues and their specialized spreaders, no heavy compressors and their attachments and no nailing guns. A roll of Elastilon weighs considerably less then glue down adhesive pails or compressors and requires only a sharp knife for a perfect installation.
Elastilon Product Manual Can Elastilon be installed over radiant heat? Use of an approved wood flooring water or electrical radiant subfloor heating system is approved when installed either within or above the concrete/wood subfloor. The heating system should be run 3 to 4 days prior to the installation at a reduced temperature of 64F (18c). Two days after the installation is complete, the temperature of the system may be raised gradually over a one week period to its desired operating temperature.
Elastilon Product Manual equilibrium or moisture balance between the new flooring with its surroundings before the installation. Very dry or humid regions usually require extended conditioning. Recommended acclimation levels maintained even after the installation will minimize board movement, excessive squeaks and gaps. Proper jobsite conditions such acclimation, moisture testing of the subfloor, the room and the new flooring are important components for a successful installation.
Elastilon Product Manual movement of the floor. A spray bottle set to the finest mist setting should be used. Once the water evaporates there will be a strong bond between the wood and the Elastilon. Be sure to apply pressure to the top of the board to set in place. This process can be used to work around door jambs or any other obstacles.
Elastilon Product Manual What are examples of flooring not recommended for use with Elastilon? It is not recommended to use Elastilon with odd lots, cabin grade, and rustic grades of hardwood flooring. If unsure please contact ElastilonUSA directly at 1-877-526-9663. How does Elastilon work with thinner boards? Although the instructions are common to the installation of Elastilon with all hardwood floors, particular attention must be given to the following when installing thinner boards. ie, ½”(12.
Elastilon Product Manual What are the Technical Specifications of Elastilon Strong? Material Properties: P.E.
Elastilon Product Manual Why Elastilon should be considered over other installation methods? For the Installer / Contractor / Builder One installation method for all rooms and wood types in any room including the basement. The best installation method of condos and apartments. Easy to install = less costs. o 50% to 70% faster than traditional installations. o Can install over almost any flat, clean stable surface excluding carpets. o No height concerns means no cutting of doors.
Elastilon Product Manual o Construction of a wood subfloor or preparation of the floor for a glue down application can very expensive and time consuming. Many DIY customers are apprehensive with installing solid hardwood flooring using nails or staples as it requires compressors, nailing guns and a lot of expertise. For those that cannot do it themselves the cost of basic installation of hardwood flooring can be more than the cost of the wood flooring itself.
Elastilon Product Manual Installation Tips Before you begin Always follow the manufacturer’s product instructions for installation and acclimation, or unless specifically stated, the guidelines of the (NWFA) the National Wood Flooring Association. OVERVIEW Elastilon is designed as a floating installation system, do not permanently fix or attach product to the subflooring or install under permanent cabinetry.
Elastilon Product Manual and indoor humidity levels of 45% - 65%. The use of a dehumidifier or a humidifier depending on the local jobsite situation may be necessary to maintain the desired results. ENVIRONMENTAL CONSIDERATIONS FOR THE JOBSITE Permanent air conditioning and heating systems need to be operational at all times. Care must be taken with wood stoves and electric heat which tend to create very dry conditions.
Elastilon Product Manual Board Replacement Instructions Simple step by step instructions on how to replace damaged boards. Step 1: Use a circular saw to make several cuts on the board that is to be replaced. The correct depth of the saw blade should be double-checked before cutting. Ideally, a 24-tooth saw blade is used. Note that the undamaged floor is protected by a piece of cardboard. To further protect the floor, the bottom of the circular saw could be covered with tape.
Elastilon Product Manual Step 3: Pick out the loose board pieces, and then use the chisel to carefully separate the remaining pieces from the surrounding boards. Be sure to cut away the Elastilon below the remaining boards so that it is completely removed from the area of the replaced board. Step 4: For your replacement boards, choose boards of the same specie and similar grain pattern as the ones you removed. Examine the boards for straightness and correct milling. Measure them precisely.
Elastilon Product Manual Step 6: With the bottom of the groove knocked off, use a planer to finish the job. Step 7: Use a chop saw to knock off the bottom on the board's grooved end. Then, on the side where you made your original cut, make a cut at a 45-degree angle (as shown above), which will allow the board to fit in more readily. Be careful not to angle the cut too close to the top of the wear layer, or it will leave a gap when the board is sanded down to the level of the rest of the floor.
Elastilon Product Manual Step 9: Use two-part epoxy if you are planning to re-sand the floor otherwise regular PVA carpenters glue can be used on top of the tongues and at the end matches. Glue all sides of the replacement board in place. Epoxy has various set-up times so be careful to allow for this. Again regular carpenters wood glue can be used, but requires a wait of 24 to 48 hours before you can sand the floor. Step 10: The glue is also applied to the top of the end match.
Elastilon Product Manual Elastilon Certified Installers Referral Program Join our growing list of certified installers for our referral program. We are often requested by Elastilon users to recommend Elastilon Certified Installers to install their floor. If you are interested in joining this program, or know of other installers that wish to join as well, we invite you to become certified on the product and be automatically added to our growing list by completing the following steps: 1.
Elastilon Product Manual Notes: ~ 22 ~
Elastilon Product Manual For more details, please visit our website www.elastilonusa.