User`s guide
EtherLoop system provisioning 6-13
Software Release 2.30 YesWare Applications User’s Guide 08-01016-01
Procedure 6-2
Provisioning Modem Connection Billing
Use this procedure to build the database of EtherLoop modems managed by
the YWS.
Action
Step Action
1 Select the Set ModeX daemon information function in the System
Maintenance section of the NSS Maintenance module. The "Configuration
parameters: modex" dialog appears as shown in Figure 6-10.
Figure 6-10
Configuration parameters: modex dialog
2 Set the Modex Daemon "ETHER_INTERFACE_NAME" value to ETH 1.
3 Select Port Manager from the YesWare Main Menu.
4 Select the Find New Modems
function to launch the "Discover EtherLoop
Modems" dialog as shown in Figure 6-11.
Figure 6-11
Discover EtherLoop Modems dialog
—continued—
Using the Find New Modems function
To use the Find New Modems function described in this procedure, the EtherLoop
modems must reside on the same LAN segment as the YWS.