Specifications

3-4
ELMo 120 Multiplexer maintenance
Revision 2.01 ELMo 120 Multiplexer Installation and Maintenance Guide 08-01023-01
End-to-end maintenance checklist
Problem Check
No voice or data service
Verify power at all points in the system
Verify connections and wiring conditions at
all points
Voice but no data service
Verify that there is not an external network
problem such as a server being down
Verify that the Ethernet card on the PC
connected to the Elite modem has been
configured
Verify that the correct type of Ethernet cable
(“straight” or “crossover”) is being used for
the application.
Verify that all LEDs on Elite modems are
green
Verify that the green LEDs at the various
Ethernet connection points are lit
Check for 10Base-T cable damage
Verify router configuration and installation
See “Voice and data connectivity
maintenance in facility room” checklist
Data but no voice service
Check dialtone at the PSTN/PBX cross-
connect to verify that there is not an external
voice network problem
Check/replace Filter card in voiceband filter
shelf
See “Voice and data connectivity
maintenance in facility room” checklist