Specifications

ELMo 120 Multiplexer maintenance
3-3
Revision 2.01 ELMo 120 Multiplexer Installation and Maintenance Guide 08-01023-01
Maintenance checklists
This section contains the maintenance checklists for resolving EtherLoop
service problems.
Voice and data connectivity maintenance in facility room
Problem Maintenance Check
No voice or data service
Verify that the correct Tip/Ring pairs are
being tested for both voice and data
Verify power at all points in the system
Check jumper connections at all cross-
connects
Verify connections and wiring conditions at
all points
Voice but no data service
Verify that the correct Tip/Ring pairs are
being tested for both voice and data
Check jumper connections
Check LEDs at intermediate hub or YesWare
Server/router connections
Check for 10Base-T cable damage
Verify that Modem card is present in correct
slot and fully seated in ELMo 120 backplane
connection
Replace Modem card to check for bad card
Verify that Ethernet Switch card is present in
correct slot and fully seated in ELMo 120
backplane connection
Replace Switch card to check for bad card
Data but no voice service
Verify that the correct Tip/Ring pairs are
being tested for both voice and data
Check jumper connections at PSTN/PBX
cross-connect
Check dialtone at the PSTN/PBX cross-
connect to verify that there is not an external
voice network problem
Verify that Filter card is present in correct slot
and fully seated in ELMo 120 backplane
connection
Replace Filter card in ELMo 120 shelf to
check for bad card