Specifications

2-16
ELMo 120 Multiplexer installation and testin
g
Revision 2.01 ELMo 120 Multiplexer Installation and Maintenance Guide 08-01023-01
Installing ELMo 120 Multiplexer connections for data-only service (continued)
Step Action
4
Connect the Amp-Champ 25-pair connector of the ELMo 120 Multiplexer
cable harness to the matchin
g
Amp-Champ 25-pair connector on the
intermediate cable. See Fi
g
ure 2-9.
Figure 2-9
ELMo 120 Multiplexer intermediate data connection
5
Route the Tip/Rin
g
pairs ori
g
inatin
g
from the Elite/CPE lines to the EtherLoop
cross-connect.
6
Terminate the Elite/CPE Tip/Rin
g
connections to the EtherLoop cross-
connect block.
7
Record the Elite/CPE Tip/Rin
g
assi
g
nments of the EtherLoop cross-connect
accordin
g
to local office procedures.
8
Secure all cables in accordance with local office procedures.
9
Record the EtherLoop connection assi
g
nments.
This concludes the ELMo 120 Multiplexer data-only installation.
10
Go to “Testin
g
the ELMo 120 Multiplexer installation” on pa
g
e 2-24.
STOP
You have completed this task.
ELMo 120 cable harness
from J1/J2 connectors
Intermediate cable from EtherLoop
data cross-connect on the MDF