Specifications

Elastic Networks 1 BitStorm 1900 Access Multiplexer
08-01101-01, Rev. 1.50 BitStorm 1900™ Installation and Maintenance Guide 1-47
BitStorm 1900 Component Requirements
Table 1-10, “BitStorm 1900 Component Requirements,” provides the
basis requirements for each component within the shelf.
Table 1-10: BitStorm 1900 Component Requirements
P. N Shelf Com-
ponents
4212
CO
Modem
Card
6306
CO
Modem
Card
6224
CO
Modem
Card
10306
CO
Modem
Card
10224
CO
Modem
Card
Special
Instructions
01-30013-01 250 W DC
power
Yes No No No No
01-00080-01 260 W DC
power
Optional Yes Yes Yes Yes Must use fan
tray*
*air filter is
required for
NEBs
compliance
01-00060-01 70 W AC
power
Optional No No No No
01-00079-01 260 W AC
power
Optional Yes Yes Yes Yes Must use MIU
and fan tray
without
an air
filter
01-30011-01 Switch Card Yes No No No No Cannot use
Switch Card
with 260 W
power cards
01-00075-01 MIU Optional Yes Yes Yes Yes
01-00084-01 Fan Tray, DC Optional Yes Yes Yes Yes
01-00084-02 Fan Tray, AC Optional Yes Yes Yes Yes
!
WARNING: POSSIBLE EQUIPMENT DAMAGE! To
comply with Telcordia GR-1089-CORE,
Outside Plant Voltage/Current Limiting
Protection is required for each Outside Plant
Exposed line.