Specifications
Appendix A: Installation Requirements Elastic Networks
A-140 BitStorm 1900™ Installation and Maintenance Guide 08-01101-01, Rev. 1.50
Table A-3, "BitStorm 1900 Weight and Dimensions" includes the shelf
weight and dimensions.
Installation Site Requirements
Equipment Location
The BitStorm 1900 Access Multiplexer should be isolated from other
machinery and should have a minimum distance of 30 inches from UV
lighting to prevent Electrostatic Discharge (ESD).
The BitStorm 1900 should not be installed in laundry rooms, work-
shops, janitorial closets, chemical storage sites, carpeted areas, or any
other locations where potentially harmful airborne particles may be
present.
Table A-4, "BitStorm Operational Requirements" includes the installa-
tion site requirements for the BitStorm 1900 shelf.
Table A-3: BitStorm 1900 Weight and Dimensions
Specification Weight (metric)
Weight (without cards) 19 lbs.
Weight (with cards) 43.4 lbs.
Height 12.1875 in.
Width 17.5 in.
Depth 12 in.
Table A-4: BitStorm Operational Requirements
Specification Requirement
Local area network
environment
TCP/IP over Ethernet
Power supply -48 V DC nominal
-46 to -56 V DC acceptable
range or 110 V AC