Specifications
Appendix A: Installation Requirements Elastic Networks
A-134 BitStorm 1900™ Installation and Maintenance Guide 08-01101-01, Rev. 1.50
• The bay must be installed and secured in accordance with standard
telecommunications industry practices
• Use an Elastic Networks Isolation Kit to isolate the bay from build-
ing structures and outside elements for "in-building" installations
(i.e., enterprise, MDU, and MTU).
• The bay must be electrically grounded according to standard tele-
communications industry practices
BS1900 System Specifications
Table A-1, "BitStorm 1900 System Specifications"shows the power
specifications for the BitStorm 1900 shelf.
Table A-1: BitStorm 1900 System Specifications
BitStorm 1900 System Specifications
Description Front Mount
4212 Full
1
Front Mount
6306 Full
2
Front Mount
6224 Full
3
Front Mount
10306
Full
4
Front Mount
10224 Full
5
Lines Per Chassis 120 Lines, 4
Megabit
60 Lines, 6
Megabit
240 Lines, 6
Megabit
60 Lines, 10
Megabit
240 Lines, 10
Megabit
Weight 43.4 lbs. 50lbs. 46 lbs. 50lbs. 46 lbs.
Height 12.1875” 12.1875” 12.1875” 12.1875” 12.1875”
Width 12” 12” 12” 12” 12”
Required Rack Units 13 13 13 13 13
Depth 12” 12” 12” 12” 12”
Cabled Depth 16” 17.5” 17.5” 17.5” 17.5”
Cabled Ear to Front (Front
Mount)
2.5” 4” 4” 4” 4”
Cabled Ear to Front (Mid
Mount)
6.25” 7.75” 7.75” 7.75” 7.75”
Cabled Ear to Back (Mid
Mount)
13.5” 13.5” 13.5” 13.5” 13.5”
Cabled Ear to Back (Mid
Mount)
9.75” 9.75” 9.75” 9.75” 9.75”
Humidity (Non-Condensing) 1% to 90% 1% to 90% 1% to 90% 1% to 90% 1% to 90%
Ambient Temp. Rating
5
o
C to 40
o
C 5
o
C to 40
o
C 5
o
C to 40
o
C 5
o
C to 40
o
C 5
o
C to 40
o
C