Specifications
2 BitStorm 1900 Installation and Testing Elastic Networks
2-80 BitStorm 1900™ Installation and Maintenance Guide 08-01101-01, Rev. 1.50
Step Procedure cont.
4.) Connect one Amp-Champ connector of an intermediate cable to
the "Line/CPE" side of the EtherLoop cross-connect block, then
connect the other end to an Amp-Champ to Dual Omni Grid cable.
5.) Connect the Amp-Champ connector of the second intermediate
cable to the "Voice" side of the EtherLoop cross-connect block,
then connect the other end to an Amp-Champ to Dual Omni Grid
cable.
6.) Connect the two Omni-Grid connectors from the EtherLoop "Line/
CPE" side to the "Dial Tone & EtherLoop OUT" ports of the filter
shelf as shown in Figure 2-15, "Line/CPE and Voice Connections
on the Filter Shelf for 6306 or 10306 Modem Cards," on page 82.
7.) Connect the two Omni-Grid connectors from the "Voice" side to the
"Dial Tone IN from PBX/PSTN" ports of the filter shelf as shown in
Figure 2-14, "Line/CPE and Voice Connections on the Filter Shelf
for 4212 Modem Cards," on page 81, Figure 2-15, "Line/CPE and
Voice Connections on the Filter Shelf for 6306 or 10306 Modem
Cards," on page 82, Figure 2-16, "Line/CPE and Voice Connec-
tions on the Filter Shelf for 6224 or 10224 Modem Cards," on page
83, and/or Figure 2-17, "Voice/Data Filter 66-Block Connections for
4212 CO Modems," on page 86. Record EtherLoop assignments.