Specifications
2 BitStorm 1900 Installation and Testing Elastic Networks
2-78 BitStorm 1900™ Installation and Maintenance Guide 08-01101-01, Rev. 1.50
Task 009: Installing Voice/Data & Filter Shelf
Connections
Use this procedure to connect the BitStorm 1900 to the EtherLoop
cross-connect in voice/data applications.
Requirements
This procedure requires the following tools and materials:
• 10-BitStorm 1900 cable harnesses
• 10-intermediate cables
• 10-BitStorm 1900 data cables
"Appendix B: Cabling Specifications," on page 143 contains the speci-
fications for the cables and wiring required in this procedure.
Step Procedure
1.) Place and secure the dedicated EtherLoop cross-connect on the
facility main distribution frame.
2.) Designate and label one side of each block as "Line/CPE," and the
other side as "Voice."
3.) Review pin and pair assignments in Figure 2-3, "Pin and Pair
Assignments for the Champ to Omni Grid Cable (part # 04-00007-
10)," on page 79.