#/- #/--5.)#!4)/.3 #/.
ELAN HOME SYSTEMS COM2 Communications Controller Preface Purpose of This Manual This manual provides step-by-step installation instructions and connection examples, along with basic user information for installation and ongoing use of the COM2 Communications Controller. This manual is written for the installer of this equipment.
COM2 Communications Controller ELAN HOME SYSTEMS Safety Information IMPORTANT SAFETY INFORMATION When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: Read Information—All the safety and operating information should be read before the appliance is operated. Follow Information—All operating and use information should be followed.
ELAN HOME SYSTEMS COM2 Communications Controller Water and Moisture—To reduce the risk of electric shock or fire, these appliances should not be used near water--––for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool. Power Cord Protection—Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the point where they exit from the apparatus.
COM2 Communications Controller ELAN HOME SYSTEMS Cart, Stand, Tripod, Bracket or Table—Use only with a cart, stand, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip over. Disconnect Device—Where the mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain operable.
ELAN HOME SYSTEMS COM2 Communications Controller If your telephone equipment causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance. But, if advance notice isn’t practical, you will be notified as soon as possible. You will be notified of your right to file a complaint with the FCC. Connection to party line service is subject to state tariffs.
COM2 Communications Controller vi ELAN HOME SYSTEMS © ELAN Home Systems 2007 • All rights reserved.
ELAN HOME SYSTEMS COM2 Communications Controller Table of Contents Purpose of This Manual ........................................................................................................................................... i Organization ........................................................................................................................................................ i Safety Information ...........................................................................................
COM2 Communications Controller ELAN HOME SYSTEMS Table of Contents (cont’d) Panel Functions ................................................................................................................................................... 1-7 Front ................................................................................................................................................................ 1-7 Figure 1-3: COM2 Front Panel Controls & Indicators.............................................
ELAN HOME SYSTEMS COM2 Communications Controller Table of Contents (cont’d) COM2 to Door Station Connections ...................................................................................................... 3-5 Figure 3-8: COM2 to DSC3 Door Station Wiring Pinout (Option 1) .............................................. 3-6 Figure 3-9: COM2 to DSC3 Door Station Wiring Pinout (Option 2) .............................................. 3-6 Figure 3-10: COM2 to DSF3 or DSS3 Door Station Wiring Pinout .....
COM2 Communications Controller ELAN HOME SYSTEMS Table of Contents (cont’d) Chapter 4 Troubleshooting Table 4-1: Table 4-2: Table 4-3: Table 4-4: Table 4-5: Telephone Troubleshooting Procedures....................................................................... 4-1 COM2 Door Station Troubleshooting Procedures........................................................ 4-2 COM2 Relay Troubleshooting Procedures ...................................................................
ELAN HOME SYSTEMS COM2 Communications Controller Chapter 1: Introduction Introduction With the COM2 Communication Controller, your multi-room audio system will be transformed into a whole-house communications network. This stand-alone component integrates intercom, telephone and home automation features with your existing audio system to seamlessly create an environment of whole house communication and control.
COM2 Communications Controller ELAN HOME SYSTEMS Automation In Mind With its relay control circuitry, the COM2 can also provide control of home automation amenities such as lighting, drapes, outside gates, even security systems. Home automation commands, such as the opening of drapes and turning lights on or off are easily executed via the telephone keypad. Nothing could be more simple or more elegant.
ELAN HOME SYSTEMS COM2 Communications Controller Selectable Door Chimes The COM2 features 10 user-selectable door chimes that let you differentiate between door stations. Unique chimes, such as sleigh bells, a fog horn and even a barking dog make for fun door announcements that can easily be changed for the occasion.
COM2 Communications Controller ELAN HOME SYSTEMS Quick Reference Telephone Features Guide Included with the COM2 Communications Controller, you will find two “Quick Reference” Telephone Feature Cards. Figure 1-2 Quick Reference Card The COM2’s phone features are easy to remember and use, but these guides will come in handy for those who are unfamiliar with the system or as a refresher. The COM2 also gives you the capability of activating up to four low voltage relays from your telephone keypad.
ELAN HOME SYSTEMS COM2 Communications Controller A Quick Explanation All telephone feature commands are initiated from the keypad of your touch tone phone. They are simple to use and easy to remember! All telephone feature commands begin with the # (pound) symbol (factory preset). NOTE: You have the option of choosing the * (star) symbol as the beginning command key. This is selectable via DIP switch number 1 on the front of the COM2.
COM2 Communications Controller ELAN HOME SYSTEMS Activate A Door Latch - If you wish to activate a door latch, simply press #, then 3 (the D key on your telephone keypad) followed by a 0 (the door station that most recently had it's DB pressed.), #, 3, 1, 0 (Door Station #1), #, 3, 2, 0 (Door Station #2), #, 3, 3, 0 (Door Station #3) or #, 3, 4, 0 (Door Station #4). The door latch relay will remain open as long as you hold the 0 key.
ELAN HOME SYSTEMS COM2 Communications Controller Incoming Calls While Paging • While in page mode, if there is an incoming call you will hear a ring over the handset every fourth ring. To access the caller, press any digit (except the “0”) or the flash-hook button. • While on a phone-to-phone intercom (#,7,0), if there is an incoming call, you will hear the phone ring over the handset every fourth ring. To access the caller press any digit except “0” or the flash-hook button.
COM2 Communications Controller ELAN HOME SYSTEMS Front Panel LED Description Figure 1-4 and Table 1-1 provide color and description of the COM2 Communications Controller front panel LEDs. 1 2 3 4 5 [ ] [ ] 6 PEEL BACK LEXAN STRIP Figure 1-4 COM2 Front Panel LEDs Table 1-1 COM2 Front Panel LED’s Item# Indication Status 1 Mute Status (Green) Solid ON During music mute function (#,6). Default is OFF.
ELAN HOME SYSTEMS COM2 Communications Controller Rear / &$Ø#..1 4#(.Ø+../ (-/43 .43/43Ø) "*2 Ø"'(,$Ø.43/43 1" 3XODØ,NMN 1" 3XODØ2SDQDN / &$ 24,Ø#! #! 31(&&$1Ø.43/432 LLØRSDQDNØNMKX /.6$1 .- .%% 35- ). 0' 6!# (: W $" /54 6)! .%4 $" /540543 -/$%, #/- #/--5.)#!4)/.3 #/.42/,,%2 ). /54 ,!"%, &0/ 0' $" /54 , 0(/.% ,).% 4%,#/ ,).% /54 ). ,%8).'4/. +9 53! s -!$% ). #().! [ 4 !, 490% &53% 2%0,!#% 7)4( 3!-% 490% !.$ 2!4).' /.,9 0/7%2 2 42)''%23 .
COM2 Communications Controller ELAN HOME SYSTEMS Door Station Microphone Input Level -Adjusts the volume level of all door station microphones. Door Station Output Level - Adjusts the output volume for all the door station speakers.
ELAN HOME SYSTEMS COM2 Communications Controller Chapter 2: COM2 System Design Overview Stand-Alone Stereo System Application The COM2 can be used in stand-alone applications without the use of an ELAN Multi-Room Controller. Figure 2-1 below shows the COM2 being utilized with a stereo receiver and a dedicated tuner for Music-On-Hold. The scenario will provide complete Paging, Door Station Communications, Music-On-Hold, and relay functions.
COM2 Communications Controller ELAN HOME SYSTEMS System6 Design Application The COM2 will provide all communication functions when used with an ELAN System6 Integrated Multi-Zone Controller. Figure 2-2 below shows an ELAN S6, and a COM2 in a six zone system. NOTE: Volume Controls with Override are NOT required in this application.
ELAN HOME SYSTEMS COM2 Communications Controller System12 Design Application The COM2 interfaces easily with the System12 Multi-Room A/V Controller. Figure 2-3 shows a System12 using variable outputs, along with a D1650 Digital Power Amplifier to control eight zones. In this scenario, volume controls are not needed since variable outputs are being used from the System12.
COM2 Communications Controller ELAN HOME SYSTEMS Z•Series System Application The COM2 will provide all communication functions when used in an ELAN Z•630-based system. Figure 2-4 below shows an ELAN Z•630, ELAN Z•660, and a COM2 in a three zone system. Note that Volume Controls with Override are NOT required in this application.
ELAN HOME SYSTEMS COM2 Communications Controller Trigger Input Design Application The COM2’s Trigger Inputs are designed to accept a dry contact closure across the “+ “ and “-” terminals. An added benefit is that the Trigger Inputs provide 12VDC on the “+” terminal and ground on the “-” terminal (see Figure 2-5). This provides the ability to illuminate lighted doorbell buttons. DRIVEWAY SENSORS NO MOTION SENSORS C NO C COM2 SUM IN PG TRIGGERS 120VAC 50/60HZ 60w POWER T.
COM2 Communications Controller ELAN HOME SYSTEMS Relay Design Application The COM2 provides four active relays that respond to telephone commands. These relays can be configured as Normally Open (NO) or Normally Closed (NC). Possible applications include garage door openers, blinds, gates, or lifts. +.6Ø5.+3 &$Ø1$+ 82 %.1Ø+(&'3(-& Ø#1 /$2 & 1 &$Ø#..1 Ø$3" "., 2 42)''%23 ).0543 -/$%, #/- #/--5.)#!4)/.3 #/.42/,,%2 ,!"%, &0/ ,%8).'4/. +9 53! s -!$% ). #().! 6 6#/ '.$ 0/7%2 .# # ./ .
ELAN HOME SYSTEMS COM2 Communications Controller Chapter 3: COM2 System Connections Overview This chapter shows COM2 Communications Controller system connections. System Control Cat-5 cable should be used for all COM2 system connections including incoming phone lines, input and output triggers, ELAN Door Stations (including camera connections), volume controls with override and relays.
COM2 Communications Controller ELAN HOME SYSTEMS CAUTION: ALWAYS remove power to the COM2 along with any other electronics equipment prior to making any connections to or from the COM2. Set the Power Switch on the back of the COM2 to the OFF position prior to making connections. Blue White/Blue Orange White/Orange Green White/Green Brown White/Brown Override IR OUT IR IN N/C N/C +12V GND N/C MUTE C45P RJ-45 to Pigtail To +12V Power Supply From IR Source (IR Sensor, Source Output, etc.
ELAN HOME SYSTEMS COM2 Communications Controller COM2 Trigger Outputs The Trigger Output choices are SUM, PG, DB1 and DB2. See Table 3-1. CAUTION: ALWAYS remove power to the COM2 along with any other electronics equipment prior to making any connections to or from the COM2. Set the Power Switch on the back of the COM2 to the OFF position prior to making connections. ØØØØØØØ$+ -Ø,4+3( 1..,Ø".-31.++$1 /@FDØ3QHFFDQØ(M "., ). 35- 0' 6!# (: W 0/7%2 4 !, 490% &53% 2%0,!#% 7)4( 3!-% 490% !.
COM2 Communications Controller ELAN HOME SYSTEMS COM2 Relays The COM2 utilizes Cat-5 connections to devices such as garage door openers, blinds, and gates which can be activated with 12 Volt or contact closure. The Relay feature allows the end user to activate these devices using any touch-tone phone in the home. CAUTION: ALWAYS remove power to the COM2 along with any other electronics equipment prior to making any connections to or from the COM2.
ELAN HOME SYSTEMS COM2 Communications Controller COM2 To Incoming CO & Phones Using an RJ-14 connector, connect TIP and RING from the incoming telephone service to the TELCO LINE1/2 connector as shown. Make identical connections from the PHONES LINE1/2 connector to the telephone distribution point. Make sure to use the four inner pins of the RJ14 connector exactly as shown in the drawing.
COM2 Communications Controller ELAN HOME SYSTEMS VBRM Video Balun To Video Switcher Video + - + - Door Station Bus White/Blue DSBlue DS+ Orange White/Orange Green White/Green Brown White/Brown Cat-5 Power Snap Lock Connector COM2 Blue White/Blue Orange White/Orange Green White/Green Brown White/Brown External 12VDC Power PWR GRD PWR GRD VIDVID+ DS DS+ Cat-5 * Splice White/Green with White /Brown VID + and Green with Brown VID - for camera runs between 500 &1000 feet.
ELAN HOME SYSTEMS COM2 Communications Controller DSF3 or DSS3 DOOR STATION Butt Splice COM2 + + - Door Station Bus Black Red White Green DS+ Blue White/Blue DS Orange White/Orange Green White/Green Brown White/Brown Cat-5 -DS+ 1RL2 Blue White/Blue Orange White/Orange Green White/Green Brown White/Brown ELECTRONIC DOOR LATCH RELEASE MECHANISM Standard ELAN RJ-45 Pin-Out PIN # COLOR CODE - + FRONT DOOR LATCH POWER SUPPLY 1 2 3 4 5 6 7 8 TAB To 110V AC BLUE WHITE/BLUE ORANGE WHITE/ORANGE G
COM2 Communications Controller ELAN HOME SYSTEMS Typical Telephone Service Connections Connecting Telephone Service & Telephone Surge Protection to the System Connect the TIP and RING for each incoming phone line from the telephone company to the TH31SRG Telephone Master Hub using a 110 punchdown tool. Up to 4 incoming lines can be attached to the TH31SRG. ELAN recommends using Cat-5 to make punchdowns to TH31SRG Telephone Master Hub.
ELAN HOME SYSTEMS COM2 Communications Controller Connecting Telephone Extensions to the TH48 Telephone Expansion Hub The TH48 Telephone Expansion Hub lets the installer connect the COM2 to up to eight dualline telephone wall plate connections or sixteen single line telephones wall plate connection*. NOTE: * In the single line configuration 8 wall plate connections would have Line 1 and 8 would be configured to Line 2, if applicable.
COM2 Communications Controller ELAN HOME SYSTEMS New Construction ELAN recommends a “home-run” wiring network using Cat-5 twisted-pair telephone wire from each telephone wall jack location to an ELAN TH48 Telephone Expansion Hub.
ELAN HOME SYSTEMS COM2 Communications Controller Retrofit Pre-existing “daisy-chained” wiring networks are perfectly compatible with the ELAN COM2 Communication Controller. #/- 4ELEPHONE -ASTER (UB W 3URGE 0ROTECTION -ODEL 4( 32' 0' $" /54 0(/.% ,).% 4%,#/ ,).% %QNLØ/GNMD "NLO@MX 6XUJH 5- ; 'LVFRQQHFW 0ORTS &ROM 4%,#/ 5 7 5 7 -/( ). -/./ $//2 34!4)/. "53 /54 ).
COM2 Communications Controller ELAN HOME SYSTEMS Connecting The COM2 To A Multi-Line Telephone system The COM2 communication features (paging, door speaker communications, relay activation, etc.) can be accessed from both Line 1 and Line 2. The TELEMUTE feature is available on both COM2 lines. NOTE: Phone-to-phone intercom (#7,0) will only work with phones on the same line. For example, you can not pick up Line 1 and intercom to someone on Line 2. "@S Ø)TLODQ Ø HMBKTCDC 4( 32' 4%,%0(/.
ELAN HOME SYSTEMS COM2 Communications Controller Digital Subscriber Line (DSL) Digital Subscriber Line, or DSL, is a batch of technologies that provide a digital connection (typically an Internet connection) over the copper wires of the local telephone network. DSL provides high speed Internet access to home consumers in Europe and North America. Telephone services were initially designed to carry “Plain Old Telephone Service” (POTS) or Public Switched Telephone Network (PSTN) calls.
COM2 Communications Controller ELAN HOME SYSTEMS Standalone Connections (Without an ELAN MultiRoom Controller) Pre-Amp/Amp Use stereo RCA patch cables to connect the COM2’s AUDIO LOOP IN to the Pre-Amp’s Main Outputs as shown. Connect the AUDIO LOOP OUT jacks to the Power Amp’s Main Inputs. This allows the COM2’s Page and Doorbell signals to be heard through the speakers connected to the power amplifier.
ELAN HOME SYSTEMS COM2 Communications Controller Stereo Receiver - Tape Loop Use stereo RCA patch cables to connect the COM2’s AUDIO LOOP IN to the Receiver’s Tape Loop Outputs as shown. Connect the AUDIO LOOP OUT jacks to the Receiver’s Tape Loop Inputs. This allows the COM2’s Page and Doorbell signals to be heard through the speakers connected to the receiver. NOTE: Only applicable when Tape Loop is active and is dependent on receiver volume level, unless auto-sense ability is built in to the receiver.
COM2 Communications Controller ELAN HOME SYSTEMS Paging & Door Chime Using Two Independent Stereo Systems These connections apply to both Pre-Amp/PowerAmp Systems and Stereo Receivers with Pre-Out/Main-In jacks. This scenario requires the use of an automatic (signal-sensing) line level A/B switch such as the Sonance AL-2 or the Niles SAS-1. Depending on the A/B switch, a slight time lag between the activation/deactivation of the page and doorbell signals between System #1 and System #2 may occur.
ELAN HOME SYSTEMS COM2 Communications Controller COM2 Trigger Outputs to SIM2 Sensor Integration Module Use the COM2’s Trigger Outputs to activate automated devices that require voltage or contact closure such as lighting controls or VIA! Touch Panel sequences using ELAN’s SIM2 Sensor Integration Module. COM2 to SIM2 Sense Input Connections DB1 Triggers Camera Video on VIA! Touch Panel LOC SYS LOCAL SYSTEM 7 1 7 1 3.
COM2 Communications Controller ELAN HOME SYSTEMS ELAN Multi-Room Controller-Based Connections COM2 to System6 Connections Use an RCA interconnect cable to connect the PAGE IN and MOH (Music On Hold) RCA jacks from the S6 to the PG/DB OUT and MOH IN (MONO) jacks of the COM2. The colors match on the jacks- Red to Red, White to White. Connect a 3.5mm mono interconnect cable, such as an ELAN IRIC from the SUM Trigger Output to the S6’s PAGE TRIG IN.
ELAN HOME SYSTEMS COM2 Communications Controller COM2 To System12 S12 MOH/Page Trigger Input Use an RCA interconnect cable to connect the PAGE IN and MOH (Music On Hold) RCA jacks from the S12 to the PG/DB OUT and MOH IN (MONO) jacks of the COM2. The colors match on the jacks- Red to Red, White to White. Connect a 3.5mm mono interconnect cable, such as an ELAN IRIC from the SUM Trigger Output to the S12’s PAGE TRIG IN.
COM2 Communications Controller ELAN HOME SYSTEMS COM2 to S12 Multi-Chassis Connections The S12 utilizes outputs for Page Audio and Page Trigger in order to facilitate multiple chassis. Use a mono RCA interconnect cable for Page Audio, and 3.5mm stereo interconnects for Page Triggers as shown in the diagram. Multiple S12 Chassis Connections Page/Door Chime/MOH 3.5mm Stereo Interconnect Cable S12 #1 S12 #2 RCA Interconnect Cable (Mono) 3.
ELAN HOME SYSTEMS COM2 Communications Controller COM2 to Z•System When connecting the COM2 to a Z•630 Multi-Room controller, use a 3.5mm mono interconnect cable (ELAN IRIC for example) from the SUM Trigger Output of the COM2 to the Z•630’s IR INPUTS Jack. The same connector is utilized for keypad connections, etc. Connect Tip (stripe) of the interconnect cable to the Brown wire (pin 7) and Sleeve to the Brown/White wire (pin 8) as shown.
COM2 Communications Controller 3-22 ELAN HOME SYSTEMS © ELAN Home Systems 2007 • All rights reserved.
ELAN HOME SYSTEMS COM2 Communications Controller Chapter 4: Troubleshooting The tables in Chapter 4 provide troubleshooting symptoms along with possible causes and corrections for the COM2 Communications Controller. Table 4-1 Telephone Troubleshooting Procedures Symptom Possible Cause/s What an authorized installer can do Phone won’t dial out during stutter tone (voice message waiting). Dialing or speed dialing before stutter tones play through. Phone won’t dial out.
COM2 Communications Controller ELAN HOME SYSTEMS Table 4-1 Telephone Troubleshooting Procedures Possible Cause/s Symptom What an authorized installer can do Phone services provided by Banks, Credit Card Companies, etc. are not responding when you are on the COM2 line. Not using #,9 system Bypass. Constant “double beep” through speakers. The telephone “OFF-HOOK” alert has been activated. Check to see if any phones are off-hook (see page 1-6 or Quick Reference Card for details).
ELAN HOME SYSTEMS COM2 Communications Controller Table 4-2 COM2 Door Station Troubleshooting Procedures Possible Cause/s What an authorized installer can do Door Station Speaker too loud and distorts during speech. Door Station Output Level is is too high. Decrease the Door Station output level by turning the DOOR STATION OUTPUT LEVEL Adjustment control located behind the LEXAN Strip on the COM2 Front Panel counterclockwise. Cannot communicate with Door Station(s). Using non touch-tone phone. 1.
COM2 Communications Controller ELAN HOME SYSTEMS Table 4-2 COM2 Door Station Troubleshooting Procedures Symptom Doorbell does not work. Possible Cause/s Door Chime Output Level is turned down. Bad, stuck or miswired Doorbell button. Door Station does not play assigned chime. Improper Door Chime assignment. Door Station DIP switch may be set incorrectly. What an authorized installer can do 1. Confirm symptom and pot adjustment levels described at left. 2. Make sure the volume controls are turned up.
ELAN HOME SYSTEMS COM2 Communications Controller Table 4-3 COM2 Relay Troubleshooting Procedures Possible Cause/s Symptom Relay(s) activation via telephone not working. Improper key sequence. Relay device inoperative or mis-wired. What an authorized installer can do 1. Confirm that correct key sequence does not activate relay. 2. Confirm that the front panel LED associated with the relay you are trying to activate illuminates after pressing the correct key sequence.
COM2 Communications Controller ELAN HOME SYSTEMS Table 4-5 COM2 Volume Control Troubleshooting Procedures Symptom Possible Cause/s Volume controls do not work when page or Door Chime is sent. VCO- and VCO+ may be reverse wired, or power + and - may be reversed. What an authorized installer can do 1. Confirm symptom and homeowner’s findings regarding. 2. Verify that VCO+ and VCO-polarity is wired properly. 3. Verify power supply polarity is wired properly. 4.
ELAN HOME SYSTEMS COM2 Communications Controller Appendix A: Specifications Table A-1 COM2 Communications Controller Specifications Item Description Power Requirements Home phone battery voltage 120V, 60Hz, 25W 48VDC Relay Type NO/NC dry contact Current Limit 4A Music-On-Hold Adjustment Range Muted to +6dB.
COM2 Communications Controller A-2 ELAN HOME SYSTEMS © ELAN Home Systems 2007 • All rights reserved.
ELAN HOME SYSTEMS COM2 Communications Controller Appendix B: Door Stations Introduction ELAN’s new DS3 Series Door Station and the COM2 Communications Controller provide you with full two-way communications and door latch control from your touch-tone telephones. A simple #-D (for Door) from any touch-tone phone allows you to speak with visitors at the door. Another simple button press (“0”) activates the door latch to let them in (if you are so inclined).
COM2 Communications Controller ELAN HOME SYSTEMS Specifications Table B-1 provides the DS Series Door Station Specifications. Table B-1 Specifications Item Description Door Station Speaker 8 ohm, sealed back mylar cone Microphone Hi-gain omni-directional condenser Door Latch Relay 12VDC coil, 2A contact rating Wiring Requirements Cat-5, 1000ft max DSC3 Color Camera Specifications Imager 1/3 in. CCD Auto Iris 1/50-1/100,000 sec. Lux .05 min. Resolution 480 Horizontal Lines Horiz.
ELAN HOME SYSTEMS COM2 Communications Controller DSC3 Door Station/ Color CCTV +DB- -DS+ 1RL2 Orange Brown Black Red White Green COLOR DOOR NEWCCTV DSC2000 STATION CAMERA / To Video Balun via Cat-5 To Door Latch { { To Video Balun via Cat-5 For best aesthetics and audio quality, (and viewing angle when positioning the DSC3), mount the unit approximately 4-1/2 to 5-1/2 feet from the ground.
COM2 Communications Controller ELAN HOME SYSTEMS Locate and adjust the DIP switches to indicate the desired door station for your location, i.e., front door = Door Station 1, back door = Door Station 2 etc. (see Figure B-3). #! #2 1+ #(/ 26(3"'$2 $3 2, #2% Ø.
ELAN HOME SYSTEMS COM2 Communications Controller Figure B-4: VBRM Video Balun NOTE: The ELAN DSC3, DSF3, or DSS3 Door Stations interface with the COM2 Communications Controller to provide door chime and door station communications functionality. Use Cat-5 for these connections. Cat-5 network cable must be used if using the DSC3 in conjunction with the VBRM Video Balun.
COM2 Communications Controller ELAN HOME SYSTEMS DSF3 & DSC3 Installation Both the DSF3 and DSC3 Door Stations are installed using the DBK1000 Door Station/Camera Rough-In Bracket (sold separately). In order to install the DSC3 or DSF3 Door Station in the DBK1000 the door station trim brackets must be mounted to the front of the DBK1000 (see Figure B-6).
ELAN HOME SYSTEMS COM2 Communications Controller 1) Use 7/16 wrench to loosen the screw and rotate the camera. 2) Make sure the camera wire is located in the upper right corner of the camera module when the DSC3 is viewed from the rear. 3) Adjust the viewing angle by carefully twisting the camera bracket. 4) Once the camera has been repositioned, tighten the bracket screw to secure the camera at the desired position.
COM2 Communications Controller ELAN HOME SYSTEMS To install the DSS3 Door Station: 1) Using the surface bracket as a template, mark and drill the four corner holes. Insert a wall anchor in to each hole. 2) Attach the surface bracket using the four surface mounting screws. NOTE: Make sure to make your electrical connections prior to mounting the door station. 3) Connect DS + and DS - using a butt splice or other appropriate connector.
Limited Warranty ELAN HOME SYSTEMS L.L.C. (“ELAN”) warrants the COM2 Communications Controller to be free from defects in materials and workmanship for the period of two years (2 years) from date of purchase. If within the applicable warranty period above purchaser discovers that such item was not as warranted above and promptly notifies ELAN in writing, ELAN shall repair or replace the item at the company's option.