Elan Digital Systems Ltd. 13 AD125 USER’S GUIDE
20 different input ranges can be achieved with the AD125. The gain
is programmed using the top four bits of SETUP REG 1 (GS0..3).
The following table summarises the gains and input ranges
available:
GAIN GS0..3 AD125 INPUT VOLTAGE RANGE (volts)
BIPOLAR UNIPOLAR
4 0h
± 0.625
0 → 1.25
2 1h
± 1.25
0 → 2.5
4/3 2h
± 1.875
0 → 3.75
1 3h
± 2.5
0 → 5.0
4/5 4h
± 3.125
0 → 6.25
2/3 5h
± 3.75
0 → 7.5
4/7 6h
± 4.375
0 → 8.75
1/2 7h
± 5.0
0 → 10.0
4/9 8h
± 5.625
2/5 9h
± 6.25
4/11 Ah
± 6.875
1/3 Bh
± 7.5
4/13 Ch
± 8.125
2/7 Dh
± 8.75
4/15 Eh
± 9.375
1/4 Fh
± 10.0