Technical data
STOP
PUMP’S OPERATION
FAN’S OPERATION
FIRING-UP MODE
BLOW-THROUGH - INTERNAL TIME
BLOW-THROUGH - OPERATING TIME
POWER SWITCH
Pic.2 Description of the regulator’s panel.
4.2. Technical data of EKOSTER2 regulator - type 3.1
1. Temperature range -9 °C up to +99 °C
2. Temperature setting +60 °C up to +80 °C
(in the type 3.4: +60 °C up to +97 °C)
3. Temperature of the pump turning on +65 °C (in the type 3.4: +65 °C up to +90 °C)
4. Blowdown regulation
working time 0-90 seconds
stopover 1-15 minutes
possibility of full blow-
through turning off
P-0
5. Hysteresis (the difference turn on- turn off) From 2 up to 9 °C
6. Maximum switching power
fan 100 W
pump 100 W
7. Main supply voltage / Frequency 230 V AC, 50 Hz
8. Maximum power taking 275 VA
9. Fan regulating power in % x 10 (regulation range from 30-100 %)
10. Outside humidity ≤ 95 %
11. Protection rating IP 40
4.1. Front panel of EKOSTER 2 regulator
4. Description of CONTROL SYSTEM
6