Technical data

7.4. Leakproof securing
Leakproof of the boiler is very important especially leakproof of the door, the exchanger and
chimney ap. Leakproof causes the fumes’ coming out of the boiler and most of all it can cause
uncontrolled burning which may cause boiler’s overheating. To ensure the exchanger’s door lea-
kproof the insulation rope should be sealed with a graphite oil or some other machine oil at least
once a week. It soften the rope and causes its tight adjoining to the boiler.
After some time of boiler’s operating (1 season for example) the door rope could get atted. To
assure right rope’s adjoining to the boiler’s door, door setting regulation is provided (regulation on
the hinge).
Hinge door setting:
a) take the door off
b) loosen the cap
c) turn the hinge 360°
d) turn a tap tight to block hinges
regulating screw.
NOTICE!
Upper and down hinge should be
regulated in the same time.
Pic10. Cleaning elements.
NOTICE!
Chimney ue’s leakproof should be controlled and if such a need occurs - it should
be cleaned out. All of the threaded elements before their unscrewing should be
lubricated with grease. Door and hinges should be lubricated temporarily as well.
blocking nut
19
The Eko-Vimar Orlański advices using SADPAL - a catalyst for wood tar burning. It is to burn up
the wood tar all over the boiler, beginning with a burner, combustion chamber and a chimney.
All details according the SADPAL use are written on a packaging. The product is available in
Eko-Vimar Orlański offer.
- Only in STANDARD version