Technical data

6. Connecting and exploitation
6.1. Connecting
Four-way mixing valve is essential for any installation. Its role is to mix hot water (contribution
water) with the one returning from the system. Water mixing is necessary as to avoidcold return
of the water” and to keep the same temperature of the boiler. What follows the temperature of he-
ating system’s feeding can be lowered to the temperature of satisfactionary warmth in the house.
Mixing valves should be used both in gravity system and with extorted ow (pump).
1. Four-way mixing valve ex. KOMEXTHERM
or MUT (available in Eko-Vimar Orlański’s
offer)
2. Circulating pump
3. Room temperature sensor (for the RK 2001
regulator) or room thermostat (for the RK
2001 and EKOSTER2 regulator)
4. ORLAN BOILER with EKOSTER 2
regulator
5. Radiator
6. OKCV operational water heater
7. Differential valve
8. Safety group
9. Cold water outlet
10. Cold water inlet
11. Pressure vessel
NOTICE!
Mixing valve 1should be set
at 50 % mixing.
Pic.5 An exemplary scheme of the Orlan boiler, four-way mixing valve and water heater connecting.
Pic.6 Safety valve - STS 20
1. ORLAN boiler
2. Pressure vessel
3. Radiator
4. Thermal drain protection -
13
connection to the boiler.
cooling valve STS 20
5. Four-way mixing valve
6. Safety group