Specifications

29
EKO BOILER MANUAL
temperature sensor
damaged
call service
regulator damaged call service
thermal protection engages
investigate reasons for boiler
overheating
no power in regulator check fuse and wiring
fan damaged call service - fan’s replacement
regulator damaged call service
fan not working
fan blocked inspect and clean the fan
bearings damaged call service - fan’s replacement
condenser damaged call service - condenser’s replacement
fan making noise fan clips loosened check, turn the clips tight
fan’s blades unclean check and clean
debris in fans cover check and clean
dirty fan blades check and clean
fan working poorly
pitch on the fan cover
check and clean
problems with startup refer to Section 6.5
chimney draught to low
(below 10 Pa)
rebuild chimney. Consider use of WKO
exhaust fan
chimney draught to intensive
(over 20 Pa)
use exhaust regulator
wood too small or too dry mix with larger humidity fuel as to
increase humidity level (in about 15-
35%)
Explosion or
“puffing” in the
firebox
clogged heat exchanger
tubes
clean the exchanger or call service –
not covered by warranty
9. Disposal and Recycling of Boiler Components
EKO boilers contain steel, electronic components, insulation and
other materials that may be subject to local, state or federal
regulations as to their proper disposal. When retiring an EKO boiler
from service, make sure that all applicable laws, rules and
regulations are observed. When in doubt, check with your local
regulating authority for scrapping and disposal guidelines.
17
Disposal and Recycling of Boiler Components
- 19 -
functioning or malfunctioning of any such component.
Repairs or replacements caused by thermal shock.
PURCHASER'S LEGAL RIGHTS: This warranty gives you specific legal rights, and you may also have other
rights which may vary from state to state. This warranty shall not be construed as inconsistent with any federal,
state or municipal law or any regulations promulgated in connection herewith.
Questions regarding this warranty may be referred to
New Horizon Corporation,Inc.
151 McGregor Drive
Sutton, West Virginia 26601
(304)765-7171,
newhorizoncorp@gmail.com
HOW AND WHERE TO GET SERVICE. Repairs or replacements under this limited warranty must be performed
by your dealer or someone authorized by him. You may be required to present this limited warranty to the dealer
before any work is performed. You must pay for any work performed which is not covered by this limited warranty
or which is not authorized by the dealer.
Disposal and recycling of boiler components
EKO boilers contain steel, electronic components, insulation and other materials that may be subject to local, state
or federal regulations as to their proper disposal. When retiring an EKO boiler from service, make sure that all
applicable laws, rules and regulations are observed. When in doubt, check with your local regulating authority for
scrapping and disposal guidelines.
Distributed in North America by:
New Horizon Corporation,Inc.
151 McGregor Drive
Sutton, West Virginia 26601
(304)765-7171
newhorizoncorp@gmail.com