User guide

CG2-SHANTY • CompactPCI GPS Receiver/Clock
- 27 -
EKF Elektronik GmbH • Philipp-Reis-Str. 4 • 59065 HAMM • Germany
Tel. +49 (0)2381/6890-0 • Fax. +49 (0)2381/6890-90 • E-Mail info@ekf.de • Internet www.ekf.com
To establish a connection between the serial port SP2 and the external DGPS receiver, a three
wire cable should be used as shown in the diagram below:
1
5
6
9
DCD
RTS
RxD
TxD
DTR
DSR
CTS
RI
GND
GND
Connection Cable RS-232
for interconnection between
CG2 serial port (SP2) and
WZ WFE97 DGPS Receiver
connectors shielded D-SUB 9
CG2-SHANTY: female connector
WZ WFE97 DGPS: male connector
cable is included with DGPS receiver
UB
RTCM Data
WZ WFE97
DGPS
CG2-SHANTY
SP2
1
5
6
9