User guide

User Guide CC3-CAJUN • Low Power CompactPCI CPU
- 7 -
EKF Elektronik GmbH • Philipp-Reis-Str. 4 • 59065 Hamm • Germany
Tel. +49 (0)2381/6890-0 • Fax. +49 (0)2381/6890-90 • info@ekf.de • www.ekf.com
Thermal
Conditions
Environmental
Conditions
Processor cooled down by passive heatsink, typical thermal resistance 13.8K/W (natural convection),
4.6K/W (forced airflow @ 200LFM). Custom specific heatsink solutions on request. Maximum ambient
operating temperature with standard heatsink:
< CC3-1: 0-40°C (natural convection cooling), 0-70°C
*
(200LFM forced airflow)
< CC3-2: 0-60°C (200LFM forced airflow), 0-70°C
*
(400LFM)
< CC3-3: 0-45°C (200LFM forced airflow), 0-65°C (400LFM), 0-70°C
*
(600LFM)
< CC3-4 0-40°C (200LFM forced airflow), 0-65°C (400LFM), 0-70°C
*
(600LFM)
*
Limited to 70°C due to other components than the processor
< Storage temperature: -40°C ... +85°C, max. gradient 5°C/min
< Humidity 5% ... 95% RH non condensing
< Altitude -300m ... +3000m
< Shock 15g 0.33ms, 6g 6ms
< Vibration 1g 5-2000Hz
EC Regulations < EN55022, EN55024, EN60950-1 (UL60950-1/IEC60950-1)
< 2002/95/EC (RoHS)
MTBF 0.113 * 10
6
h
Typical
Calculating
Performance
PCMark2002 under Windows 2000, CPU/MEM Score
1274/886 @400MHz 1990/933 @650MHz tbd @800MHz 2854/1467 @933MHz
Subject to technical changes