User`s manual

Software Manual • EKF Intelligent I/O Controller Family On
CompactPCI
- 15 -
EKF Elektronik GmbH * Philipp-Reis-Str. 4 * D-59065 HAMM (Germany)
Tel. +49 (0)2381/6890-0 * Fax. +49 (0)2381/6890-90 * E-Mail info@ekf.de * Internet http://www.ekf.de
"
ACCEPTANCE_SINGLE
"=dword:00000001
build a single acceptance filter when set
(ACCEPTANCE_SINGLE != 0),
else a dual filter configuration is created.
1
)
"
BASE_CLOCK
"=dword:016E3600 CANbus clock frequency in Hz, depends on
the oscillator mounted on the board, allowed
values are:
8000000, 16000000, 24000000.
"
DEVICE_TYPE
"=dword:00000001 specifies the type of the I/O device:
0 or absent defines a serial port,
1 defines a CANbus port.
Note:
1
) The default acceptance filter created by the driver setup for all CANbus ports is configured
so that the port accepts any frame. See the SJA1000 Data Sheet for details how to create an
acceptance filter.
Restart The Device Driver
After any changes have been made to the registry entries a restart of the driver is necessary.
This is best done via the
Devices Menu
of the
Control Panel
(Windows NT4 only). First stop
the driver and then start it again.
On Windows 2000 reboot the system to take the changes affect.
Look in the event list to check that your changes haven't done any strange things.