Operating instructions
52
8.2
INSTALLATION USING AN EXTERNAL SWITCH AND CONSUMER LOAD
ekey
®
TOCAhome integra control panel and ekey
®
TOCAhome integra finger scanner
together with a motor lock. Moreover an external device is connected via relay 2. All
components are integrated in the door.
This example shows how to install the ekey
®
TOCAhome integra control panel when using
a motor lock as well as an external switch (e.g. intercom) in order to activate a consumer
load (alarm system, garage door drive mechanism, rejection relay for ekey
®
TOCAhome
pc integra, etc.)
Control panel
Connection to the finger scanner
(type A cable)
Connection to the motor lock or
to the electric strike
(type C cable)
Switching impuls
Supply
+
Supply
-
Main cable
(type B cable)
Yellow Terminal 2
White Supply + (or AC)
Brown Supply - (or AC)
Blue Input terminal 1
Grey
Input terminal
2
Pink Relay 2 C
Red Relay
2 NO / NC
G
reen Terminal
1
ext. switch
supply
Electric strike
(or garage door)