Operating instructions
42
6.1
CONNECTOR CONFIGURATION OF THE INTEGRA CONTROL PANEL
X3: Connector set to the finger scanner
Pin No.
Cable color Function
1 Yellow RS485 communication (terminal 2)
2 Green RS485 communication (terminal 1)
3 Brown Power supply (terminal 3)
4 White Power supply (terminal 4)
JMP2: Defines how relay 2 should work
Normally open contact Normally closed contact
(NO) (NC)
X6: Relay 1 screw terminal to connect the motor lock
Terminal No.
Function
1 Power supply motor lock + (equ. white X1)
2 Power supply motor lock - (equ. brown X1)
3 Switching impulse (switched white X1)
X1: Main connector plug
Pin No. Cable color Function
1 Blue Gate input terminal 1
2 Grey Gate input terminal 2
3 Yellow ekey TOCAhome terminal 2
4 Green ekey TOCAhome terminal 1
5 Brown Power supply DC- or AC
6 White Power supply DC+ or AC
7 Pink Relay 2 C
8 Red Relay 2 NO / NC (see JMP1)
3
2
1
1
3
4
2
1
2
3
1
5
4
8
JMP2