Installation manual

6. Initial InstallationDiamond digital
87
6.11.1 PRECONDITIONS
Loading the software into panel controller and E-box controller requires the follo-
wing equipment:
Personal computer IBM or compatible with 3.5-inch HD disk drive
RS-232 interface 9-pin D-type
Cable between PC and the respective controllers in the switchers (connnection
see below). In most cases COM 1, when using COM 2, MSKERMIT.INI has to
be matched.
Change SET PORT 1 to SET PORT 2 using
EDIT MSKERMIT.INI
Diamond digital
EBox Controller
EBox Connector Board
Panel Controller
Panel Connector Board
PC AT
9-pol D-sud
female
9-pol D-sub
male
Pin 7 and 9
not assigned
1:1
PC XT oder PS/2
25-pol D-sub
female
9-pol D-sub
male
Pin 7 and 9
not assigned
2
3
5
2
3
7
RxD
TxD
GND
TxD
RxD
GND
Diamond digital
EBox Controller
EBox Connector Board
Panel Controller
Panel Connector Board