Installation manual

5. Connection and StartupDiamond digital
51
Item
No.:
Socket / Connector
Description
Socket type
Connector type
Function
1
AC POWER IN IEC-320, CEE-22 Convenience outlet for power supply to the E-
box. The convenience outlet contains a mains
filter as well as the two unit fuses.
Fuse rating: 2 x 10A slow-blow
The factory-adjusted supply voltage is indi-
cated.
Caution
Double-pole or neutral fusing.
After operation of the protective device, parts of
the equipment that remain under voltage might
represent a hazard during servicing.
2
PE M6 threaded pins Terminal screw for unit earthing
PE protective earth
See section 5.1 ”Connecting Power and Earth
Lines”.
3 3 unit blowers
4 J1, J2
TALLY OUT 1 / 2
50-pin D-type
male
Tally output sockets (1) for indicating the picture
sources 1 ... 32.
Tally output sockets (2) for indicating the picture
monitors assigned to the diverse outputs.
5 J3
GPI INPUT/OUTPUT
25-pin D-type
female
General-purpose interface connector with 8 in-
put channels and 8 output channels.
6 J4, J5
TALLY IN 1 / 2
9-pin D-type
female
Tally input sockets for supplying the tally in-
formation of succeeding units.
7 J45-J52, J55-J62
J65-J72, J75-J82
INPUTS
BNC / Serial Comp
CCIR 656
32 switcher main inputs.
8 J24-J30
AUXILIARY OUTPUTS
BNC / Serial Comp
CCIR 656
1 ... 6 additional switcher outputs via which ex-
ternal and internal video signals can be sup-
plied.
9 PE/TE M4 threaded pins Terminal screws for technical earth (TE) and
protective earth (PE).
TE technical earth
PE protective earth
10 J6, J7
REMOTE
BNC / 50 Ohm
IEEE 802.3
Cheapernet connector for connection between
E-box and control panel or further control units
in the network.
For further information see the section ”Cheap-
ernet Specifications”.
Note:
In the latest version, only jack J23 is equipped.
For interconnection the signals a BNC-T-plug is