Installation manual
5. Connection and StartupDiamond digital
47
Item
No.:
Socket / Connector
Description
Socket type
Connector type
Function
1 Unit blower
2 J4
TALLY OUT 1
50-pin D-type
male
Tally output sockets for indicating the picture
sources 1 ...16.
3 J8
TALLY OUT 2
50-pin D-type
male
Tally output sockets for indicating the picture
monitors assigned to the diverse outputs.
4 J9, J14, J19, J24
MAIN OUTPUT 1..4
BNC / Serial Comp
CCIR 656
Main outputs of the production switcher.
5 J22, J23
REMOTE
BNC / 50 ohms
Cheapernet connector for connection between
E-box and control panel or further control units
in the network. For further information see the
section ”Cheapernet Specifications”.
Note:
In the latest version, only jack J23 is equipped.
For interconnection the signals a BNC-T-plug is
included.
6 J31
CLEAN FEED
BNC / Serial Comp
CCIR 656
Switcher output without considering the DSK
level.
7 J35
GPI INPUT/OUTPUT
25-pin D-type
female
General-purpose interface connector with 8 in-
put channels and 8 output channels.
8 J39
PRESET
BNC / Serial Comp
CCIR 656
Switcher preview output supplies the current
signal of the preset row.
9
TE / PE M4 threaded pins Terminal screws for unit earthing
PE protective earth
TE technical earth
When leaving the factory, both terminal screws
are shorted with a jumper.
10
J1
AC POWER IN
IEC-320, CEE-22 Convenience outlet for power supply to the E-
box. The convenience outlet contains a mains
filter as well as the two unit fuses.
Fuse rating: 2 x 10A slow-blow.
The factory-adjusted supply voltage is indi-
cated.
Caution
Double-pole or neutral fusing.
After operation of the protective device, parts of
the equipment that remain under voltage might
represent a hazard during servicing.