Installation manual
4. Mounting the Control PanelsDiamond digital
39
4.5 FASTENING
For fastening the control panels RPD 5, RPD 10, RPD 20 and RPD 30 in the master
control desk, bores are provided in the frame of the lower control panel part. The
respective lower control panel part can be fastened with countersunk wood screws
with a diameter of 4 mm. The length of the screw depends on the plate thickness
of the master control desk. A set with mounting parts is included in the delivery of
the switcher.
4.6 PROFILE SET
For the different control panels of the switcher family, black anodized profile ledges
are available as an accessory, to compensate the different heights between desk
plate and control panel.
Control panel
Profil ledge
Desk plate
underdesk part
10mm
22 mm
1 mm
When mounting, slide the profile ledge under the edge of the underdesk part. The
ledges are screwed together with the underdesk part into the desk plate.
When upgrading the switcher types DD5 and DD10, two holes each have to be
bored in the right and left (DD10) or front and rear (DD5) edge of the underdesk
part for fastening the profile ledges. The holes have to be countersunk to enable
fastening the underdesk part with countersunk screws.
The following profile sets are available:
Switcher Number of profils Type Order No.
DD5 links, rechts, vorne, hinten RC 1885 2 351 670 010
DD10 links, rechts, vorne, hinten RC 1861 2 351 660 010
DD20 links, rechts, vorne RC 2008 2 351 680 010
DD20M links, rechts, vorne, hinten RC 2062 2 351 720 010
DD30 links, rechts, vorne RC 1842 2 351 690 010