Installation manual
2. Technical DataDiamond digital
21
2.1.6 ENVIRONMENTAL DATA
– Storage temp. E-box - 20
o
C - + 70
o
C
– Storage temp. contr. pan. 0
o
C - + 70
o
C (32
o
- 158
o
F)
– Operating temp. E-box + 5
o
C - +35
o
C
For operation within specs + 10
o
C - +30
o
C
Op. temp. control panel + 5
o
C - +35
o
C
– Ventilation E-box 140 m
3
/h
– Relative humidity 80 % non-condensing
– Electromagn. compatibility (EMC) EN 55022, Class B
FCC (47CFR) PART 15 Subp J Class A
IEC 801-3, 3 V/m
– ESD IEC 801-2, 8 kV
2.1.7 MECHANICAL DATA
– Dimensions E-box 212(h) x 483(w) x 470(d) mm, (19”, 5 RU)
1 RU under the electronics box has to be
left free for ventilation and slide-in rails
– Dimensions contr. panel 373(h) x 482(w) x 97.5(d) mm
– Cutout meas. contr. panel 449 x 358 mm
– Ventilation E-box Suction port: left side panel
Blow-out port: rear top
– Weight E-box 20 kg
– Weight control panel 7 kg
– Mechanical stress vibration IEC 68-2-6,
shock IEC 68-2-29
tilt fall IEC 68-2-31,
– Color E-box dark mushroom, Philips 10709/G8
– Color control panel ultra dark grey, Philips 10714/G8